Is MRI-Based CFD Able to Improve Clinical Treatment of Coarctations of Aorta?
- 16 September 2014
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (1) , 168-176
Abstract
Pressure drop associated with coarctation of the aorta (CoA) can be successfully treated surgically or by stent placement. However, a decreased life expectancy associated with altered aortic hemodynamics was found in long-term studies. Image-based computational fluid dynamics (CFD) is intended to support particular diagnoses, to help in choosing between treatment options, and to improve performance of treatment procedures. This study aimed to prove the ability of CFD to improve aortic hemodynamics in CoA patients. In 13 patients (6 males, 7 females; mean age 25 ± 14 years), we compared pre- and post-treatment peak systole hemodynamics [pressure drops and wall shear stress (WSS)] vs. virtual treatment as proposed by biomedical engineers. Anatomy and flow data for CFD were based on MRI and angiography. Segmentation, geometry reconstruction and virtual treatment geometry were performed using the software ZIBAmira, whereas peak systole flow conditions were simulated with the software ANSYS® Fluent®. Virtual treatment significantly reduced pressure drop compared to post-treatment values by a mean of 2.8 ± 3.15 mmHg, which significantly reduced mean WSS by 3.8 Pa. Thus, CFD has the potential to improve post-treatment hemodynamics associated with poor long-term prognosis of patients with coarctation of the aorta. MRI-based CFD has a huge potential to allow the slight reduction of post-treatment pressure drop, which causes significant improvement (reduction) of the WSS at the stenosis segment.Keywords
This publication has 26 references indexed in Scilit:
- MRI‐based computational fluid dynamics for diagnosis and treatment prediction: Clinical validation study in patients with coarctation of aortaJournal of Magnetic Resonance Imaging, 2014
- Numerical blood flow simulation in surgical corrections: what do we need for an accurate analysis?Journal of Surgical Research, 2014
- The Impact of MRI-based Inflow for the Hemodynamic Evaluation of Aortic CoarctationAnnals of Biomedical Engineering, 2013
- Computational fluid dynamics in congenital heart diseaseCardiology in the Young, 2012
- Comparison of Surgical, Stent, and Balloon Angioplasty Treatment of Native Coarctation of the AortaJACC, 2011
- Effects of Disturbed Flow on Vascular Endothelium: Pathophysiological Basis and Clinical PerspectivesPhysiological Reviews, 2011
- Assisted Fontan procedure: animal and in vitro models and computational fluid dynamics study☆☆☆Interactive CardioVascular and Thoracic Surgery, 2010
- Vascular Adaptation and Mechanical Homeostasis at Tissue, Cellular, and Sub-cellular LevelsCell Biochemistry and Biophysics, 2007
- CFD analysis in an anatomically realistic coronary artery model based on non-invasive 3D imaging: comparison of magnetic resonance imaging with computed tomographyThe International Journal of Cardiovascular Imaging, 2007
- Coarctation of the aorta. Long-term follow-up and prediction of outcome after surgical correction.Circulation, 1989