Retracted: Peri‐implant bone reactions to immediate implants placed at different levels in relation to crestal bone. Part I: a pilot study in dogs
- 24 March 2011
- journal article
- retracted article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 23 (2) , 228-235
Abstract
The aim of the present study was to evaluate bone remodeling and bone-to-implant contact (BIC) after immediate placement at different levels in relation to the crestal bone of Beagle dogs. The mandibular bilateral second, third and fourth premolars of six Beagle dogs were extracted and six implants were immediately placed in the hemi-arches of each dog. Randomly, three cylindrical and three tapered implants were inserted crestally (control group) and 2 mm subcrestally (experimental group). Both groups were treated with a minimal mucoperiosteal flap elevation approach. A gap from the buccal cortical wall to the implant was always left. Three dogs were allowed a 4-week submerged healing period and the other three an 8-week submerged healing period. The animals were sacrificed and biopsies were obtained. Biopsies were processed for ground sectioning. Histomorphometric analysis was carried out in order to compare buccal and lingual bone height loss, and BIC between the two groups. All implants osseointegrated clinically and histologically. Healing patterns examined microscopically at 4 and 8 weeks for both groups (crestal and subcrestal) yielded similar qualitative bone findings. The distance from the top of the implant collar to the first BIC in the lingual crest (A-Lc) showed a significant difference (P=0.0313): 1.91 ± 0.2 mm in the control group and 1.08 ± 0.2 mm in the experimental group. There was less bone resorption in subcrestal implants than crestal implants. The mean percentage of newly formed BIC was greater with the cylindrical implant design (46.06 ± 4.09%) than with the tapered design (32.64 ± 3.72%). These findings suggest that apical positioning of the top of the implant does not jeopardize bone crest and peri-implant tissue remodeling. However, less resorption of the Lc may be expected when implants are placed 2 mm subcrestally.Keywords
This publication has 30 references indexed in Scilit:
- Influence of interimplant distances and placement depth on peri‐implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogsClinical Oral Implants Research, 2010
- Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installationClinical Oral Implants Research, 2006
- Tissue modeling following implant placement in fresh extraction socketsClinical Oral Implants Research, 2006
- Early loading of non‐submerged titanium implants with a sandblasted and acid‐etched surfaceClinical Oral Implants Research, 2005
- Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dogJournal of Clinical Periodontology, 2005
- Dimensional ridge alterations following tooth extraction. An experimental study in the dogJournal of Clinical Periodontology, 2005
- Hard‐tissue alterations following immediate implant placement in extraction sitesJournal of Clinical Periodontology, 2004
- The influence of a biomaterial on the closure of a marginal hard tissue defect adjacent to implantsClinical Oral Implants Research, 2004
- Resolution of bone defects of varying dimension and configuration in the marginal portion of the peri‐implant boneJournal of Clinical Periodontology, 2004
- A Prospective Clinical Trial of Endosseous Screw‐Shaped Implants Placed at the Time of Tooth Extraction Without AugmentationJournal of Periodontology, 1998