The Phase-II project of the China Spallation Neutron Source (CSNS-II) adopts a parallel construction-and-operation mode to minimize interference with ongoing scientific research. However, this mode presents severe radiation protection challenges. The project requires excavation of overlying soil outside the existing tunnel for tunnel connection; after soil removal, the simulated dose rate outside the tunnel reaches 5.5 mSv/h, considerably exceeding the safety limit, necessitating temporary shielding. Shielding design based on the conventional 1 W/m beam loss assumption is infeasible due to high cost and insufficient space. Accordingly, this work performs inverse estimation of beam loss via in-situ radiation measurements to optimize the temporary shielding design. Given the uncertainty of beam loss, continuous monitoring of radiation dose outside the shielding is required, but conventional fixed dosimeters are unsuitable owing to the lack of stable power supply at the construction site. A solar-powered mobile radiation monitoring system was therefore developed to enable long-term continuous monitoring in off-grid construction areas. The monitoring data are integrated into the radiation safety interlock system, which automatically cuts off the beam when the dose rate exceeds the threshold due to beam loss, thereby mitigating radiation risks. Furthermore, to ensure occupational exposure control for construction personnel — who cannot wear personal dosimeters on-site — combined dosimeters are deployed at key dose concern locations, implementing an area-monitoring-based surrogate for personal dosimetry. Field application demonstrates that the mobile monitoring system realizes long-term continuous monitoring over multiple accelerator operation cycles, and the temporary shielding reduces the dose rate in the unrestricted construction zone to below the management target of 0.25 μSv/h. The results effectively guarantee radiation safety during CSNS-II parallel construction and operation, and provide technical reference for similar large-scale scientific facilities.Keywords
This publication has 11 references indexed in Scilit:
- Radiation safety challenges in plasma acceleratorsJournal of Physics: Conference Series, 2026
- Design of the resonance extraction scheme for the upgrade project of the China Spallation Neutron SourceJournal of Instrumentation, 2025
- Research on intelligent search-and-secure technology in accelerator hazardous areas based on machine visionNuclear Science and Techniques, 2024
- A distributed and interconnected network of sensors for environmental radiological monitoringRadiation Measurements, 2020
- Beam commissioning and beam loss control for CSNS acceleratorsJournal of Instrumentation, 2020
- China's first pulsed neutron sourceNature Materials, 2016
- Radiation protection, radiation safety and radiation shielding assessment of HIE-ISOLDERadiation Protection Dosimetry, 2013
- Analysis of radiation environmental safety for China's Spallation Neutron Source (CSNS)Chinese Physics C, 2010
- Comparison between formulas of rotational band for axially symmetric deformed nucleiChinese Physics C, 2008
- ASSESSMENT OF OCCUPATIONAL EXPOSURE DUE TO EXTERNAL SOURCES OF RADIATIONHealth Physics, 2000