Purpose. Robotic-assisted laparoscopic radical prostatectomy (RALP) has become a standard treatment choice for localized prostate cancer. RALP requires a steep Trendelenburg position, which leads to a significant increase in intraocular pressure (IOP). This study evaluated the effect on the retinal structure and function in patients undergoing RALP. Methods. Standard automated perimetry (SAP) and optical coherence tomography (OCT) were performed in 20 males scheduled for RALP at 1 month and 1 day before the operation and at 1 and 3 months after the operation. IOP measurements were made in the supine position at 5 min after intubation under general anesthesia (T1), at 6 discrete time points (5, 30, 60, 120, 180, and 240 min; T2-7), and at 5 min after returning to a horizontal supine position (T8). Serial retinal nerve fiber layer (RNFL) thicknesses and visual field progression were assessed using the guided progression analysis software program. RNFL thickness progression and visual field progression were evaluated by event analysis. Results. Average IOP (mmHg) for each time point was as follows: T1 = 12.3 ± 2.6, T2 = 20.4 ± 4.2, T3 = 23.3 ± 3.8, T4 = 24.0 ± 3.2, T5 = 24.3 ± 3.4, T6 = 27.1 ± 7.2, T7 = 29.8 ± 8.7, and T8 = 20.1 ± 4.4. During RALP, IOP significantly increased. There was no progression of the visual field and RNFL thickness after surgery or any other ocular complications found. Conclusions. Although IOP significantly increased during RALP, there were no significant changes in the retinal structure and function between the pre- and postoperation observations.Keywords
Funding Information
- Ministry of Education, Culture, Sports, Science and Technology (26462689)
This publication has 21 references indexed in Scilit:
- Intraocular Pressure During Robotic-assisted Laparoscopic Procedures Utilizing Steep Trendelenburg PositioningJournal of Glaucoma, 2015
- The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomyBritish Journal of Ophthalmology, 2013
- Impact of Minimally Invasive Surgery on Medical Spending and Employee AbsenteeismJAMA Surgery, 2013
- The Effects of Steep Trendelenburg Positioning on Intraocular Pressure During Robotic Radical ProstatectomyAnesthesia & Analgesia, 2009
- A prospective, non‐randomized trial comparing robot‐assisted laparoscopic and retropubic radical prostatectomy in one European institutionBJU International, 2009
- Posterior Ischemic Optic Neuropathy After Minimally Invasive ProstatectomyJournal of Neuro-Ophthalmology, 2007
- Case reports and small case series: LASIK-associated visual field loss in a glaucoma suspect.2001
- Visual field defect associated with laser in situ keratomileusisAmerican Journal of Ophthalmology, 2000
- Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons.2000
- Differential Light ThresholdArchives of Ophthalmology (1950), 1984