Hydraulic Characterization of Implantable Rotary Blood Pumps
- 18 October 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1618-1627
Abstract
Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine their interaction with the cardiovascular system. A systematic comparison in this regard has not yet been performed for different clinically used RBPs. Aim of this study was to describe the hydraulic characteristics of four RBPs with a universal mathematical model and to compare their behavior under clinical operating conditions. Methods: First, static and dynamic pump properties of four RBPs (HVAD, Heartmate II, Heartmate 3 and Incor) including their peripheral components were identified in an in-vitro setup; results were translated into mathematical models based on principles of turbomachinery including the low and backflow region. Second, the four hydraulic models were compared in a numerical simulation of the cardiovascular system for full and partial support conditions. Results: A model structure applicable to each of the investigated RBPs was developed. Deviations between simulated and measured signals for static and dynamic properties were small (2.6 $\pm$ 0.5 mmHg, 0.38 $\pm$ 0.14 L/min, respectively). For a simulated partial support condition, flow pulsatility ranged from 4.1 (Incor) to 9.1 L/min (HVAD). Negative flow rates during diastole were observed in 3 out of 4 pumps. Conclusion: Hydraulic properties differ greatly between the investigated RBPs, with flat characteristics for the HVAD and Heartmate II and steeper curves for the Heartmate 3 and especially the Incor. Significance: Hydraulic characteristics of implantable RBPs are particularly important at lower pump flow rates if backflow is to be avoided. For further research we provide dynamic hydraulic models of the four RBPs including their periphery.
Keywords
Funding Information
- Stavros Niarchos Foundation
This publication has 34 references indexed in Scilit:
- Minimally Invasive Thoratec Heartmate II Implantation in the Setting of Severe Thoracic Aortic CalcificationThe Annals of Thoracic Surgery, 2013
- Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practiceThe Journal of Heart and Lung Transplantation, 2013
- Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular FunctionArtificial Organs, 2012
- Design Concepts and Principle of Operation of the HeartWare Ventricular Assist SystemASAIO Journal, 2010
- Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapyThe Journal of Heart and Lung Transplantation, 2010
- Numerical Modeling of Hemodynamics with Pulsatile Impeller Pump SupportAnnals of Biomedical Engineering, 2010
- Partial Mechanical Long-Term Support with the CircuLite® Synergy® Pump as Bridge-to-Transplant in Congestive Heart FailureThe Thoracic and Cardiovascular Surgeon, 2010
- A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental ValidationASAIO Journal, 2008
- Convergence Properties of the Nelder--Mead Simplex Method in Low DimensionsSIAM Journal on Optimization, 1998
- Clinical Application of a Newly Developed Autoflow Control System for the Terumo Centrifugal Pump: From External Control to Built‐in Direct ControlArtificial Organs, 1996