Comparison of acceleration signals of simulated and real-world backward falls
Authors:
- J. KlenkJ. Klenk
- C. BeckerCBC. Becker
- F. LiekenFLF. Lieken
- S. NicolaiSNS. Nicolai
- W. MaetzlerWMW. Maetzler
- W. AltWAW. Alt
- W. ZijlstraWZW. Zijlstra
- J.M. HausdorffJHJ.M. Hausdorff
- R.C. van LummelRLR.C. van Lummel
- L. ChiariL. Chiari
- U. LindemannULU. Lindemann
- 30 November 2010
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (3) , 368-373
Abstract
Most of the knowledge on falls of older persons has been obtained from oral reports that might be biased in many ways. Fall simulations are widely used to gain insight into circumstances of falls, but the results, at least concerning fall detection, are not convincing. Variation of acceleration and maximum jerk of 5 real-world backward falls of 4 older persons (mean age 68.8 years) were compared to the corresponding signals of simulated backward falls by 18 healthy students. Students were instructed to "fall to the back as if you were a frail old person" during experiment 1. In experiment 2, students were instructed not to fall, if possible, when released from a backward lean. Data acquisition was performed using a tri-axial acceleration sensor. In experiment 1, there was significantly more variation within the acceleration signals and maximum jerk was higher in the real-world falls, compared to the fall simulation. Conversely, all values of acceleration and jerk were higher for the fall simulations, compared to real-world falls in experiment 2. The present findings demonstrate differences between real-world falls and fall simulations. If fall simulations are used, their limitations should be noted and the protocol should be adapted to better match real-world falls.Keywords
Funding Information
- Robert Bosch Foundation
- European Commission
This publication has 28 references indexed in Scilit:
- Clinical and dual‐tasking aspects in frequent and infrequent fallers with progressive supranuclear palsyMovement Disorders, 2010
- A comparison of automatic fall detection by the cross-product and magnitude of tri-axial accelerationPhysiological Measurement, 2009
- Low stiffness floors can attenuate fall-related femoral impact forces by up to 50% without substantially impairing balance in older womenAccident Analysis & Prevention, 2009
- A proposal for the classification and evaluation of fall detectorsIRBM, 2008
- Inability to get up after falling, subsequent time on floor, and summoning help: prospective cohort study in people over 90BMJ, 2008
- Systematic review of definitions and methods of measuring falls in randomised controlled fall prevention trialsAge and Ageing, 2006
- SIC Task Force appraisal of clinical diagnostic criteria for parkinsonian disordersMovement Disorders, 2003
- Age Differences in Using a Rapid Step To Regain Balance During a Forward FallThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 1997
- Hip impact velocities and body configurations for voluntary falls from standing heightJournal of Biomechanics, 1996
- Etiology and prevention of age-related hip fracturesBone, 1996