Effect of Detection Parameters on Automated Electroencephalography Spike Detection Sensitivity and False-Positive Rate
Authors:
- Lawrence Ver HoefLHLawrence Ver Hoef
- Rotem ElgavishRERotem Elgavish
- Robert C. KnowltonRKRobert C. Knowlton
- 1 February 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 27 (1) , 12-16
Abstract
Most seizure monitoring units use the Gotman algorithm or a variation on it for EEG spike detection, but the effect of various detection parameters on its accuracy has not been well established. The authors report sensitivities and false-positive rates for several different sets of detection parameters. Nine patients were studied. For each patient, 6 hours of EEG data were analyzed using five different sets of spike detection parameters including combinations of amplitude thresholds, state-dependent spike detection and advanced artifact rejection. Automated spike detections were compared with spikes found on visual EEG review. Mean spike detection sensitivities for the different parameter sets ranged from 0.09 to 0.34. The highest sensitivity occurred with an amplitude threshold of 4, state-dependent spike detection turned on and advanced artifact rejection turned off. Mean rates of false-positives ranged from 4.2 to 48.6 per hour. The highest false-positive rate occurred with the same set of detection parameters that produced the highest sensitivity. The sensitivity of spike detection with the Gotman algorithm is relatively low. The data favor using a lower amplitude threshold and not using advanced artifact rejection. The false-positive rate increases with improved sensitivity, but it is still within an acceptable range for clinical application.Keywords
This publication has 7 references indexed in Scilit:
- Improvement in the performance of automated spike detection using dipole source features for artefact rejectionClinical Neurophysiology, 2003
- Spike detection: a review and comparison of algorithmsClinical Neurophysiology, 2002
- Visual and Automatic Investigation of Epileptiform Spikes in Intracranial EEG RecordingsEpilepsia, 1999
- Evaluation of a computerized system for recognition of epileptic activity during long-term EEG recordingElectroencephalography and Clinical Neurophysiology, 1994
- State dependent spike detection: validationElectroencephalography and Clinical Neurophysiology, 1992
- State-dependent spike detection: concepts and preliminary resultsElectroencephalography and Clinical Neurophysiology, 1991
- Automatic recognition and quantification of interictal epileptic activity in the human scalp EEGElectroencephalography and Clinical Neurophysiology, 1976