Accuracy of blood flow values determined by arterial spin labeling: A validation study in isolated porcine kidneys
Authors:
Open Access
- 25 July 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (2) , 353-358
Abstract
Purpose To validate the accuracy of quantitative blood flow values determined using pulsed arterial spin labeling (ASL) in the preserved and reperfused porcine kidney. Materials and Methods Ex vivo porcine kidneys were perfused with whole blood under physiological conditions, in particular including pulsatile flow. Total flow through the kidney was determined using an ultrasound flowmeter. ASL measurements at two different inversion times and four different flow rates in the range of 70–210 mL/100 mL*minute were performed. Absolute values of blood flow and arterial transit times were determined in the kidney cortex. Results The quantitative values were in good agreement with the reference values obtained after calibration of the total flow. The greatest difference observed was 13%. Conclusion Isolated organ hemoperfusion allows validating perfusion imaging techniques. The experimental setup enables long-term radiotherapeutic or toxicological studies using noninvasive ASL to monitor blood flow quantitatively. J. Magn. Reson. Imaging 2007;26:353–358.Keywords
This publication has 15 references indexed in Scilit:
- Perfusion Imaging Using Arterial Spin LabelingTopics in Magnetic Resonance Imaging, 2004
- Preliminary Evaluation of EVP 1001-1Investigative Radiology, 2003
- Hemoperfused Isolated Porcine Slaughterhouse Kidneys as a Valid Model for Pharmacological StudiesJournal of Pharmaceutical Sciences, 2003
- A Model of Isolated Autologously Hemoperfused Porcine Slaughterhouse KidneysNephron, 2002
- Assessment of T1 and T effects in vivo and ex vivo using iron oxide nanoparticles in steady state—dependence on blood volume and water exchangeMagnetic Resonance in Medicine, 2002
- QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labelingMagnetic Resonance in Medicine, 1999
- A general kinetic model for quantitative perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 1998
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences of the United States of America, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992