Impact of Sensor Placement and Gait Dynamics on Off-Body MBAN Channel Characteristics: A Comprehensive Performance Evaluation of BER and Data Throughput at 2.36–2.39 GHz
Open Access
- 27 March 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 51687-51701
Abstract
Medical body area networks (MBANs) operating in the 2360–2390 MHz band enable continuous health monitoring across a wide range of clinical and home-care applications. This paper presents a comprehensive performance evaluation of off-body MBAN links based on Monte Carlo simulations using empirically derived channel models from the IEEE 802.15.6 standard. Two transmitter locations, chest mounted and right wrist mounted sensors, are investigated under standing and walking conditions for distances ranging from 1 m to 4 m and angular orientations of 0°, 90°, 180°, and 270°. The impact of sensor placement and gait dynamics on bit error rate (BER) and theoretical maximum achievable throughput is analyzed. Constraints and practical hardware limitations are considered by restricting transmit power to specific absorption rate (SAR) and by analyzing energy consumption using parameters from commercial wearable transceivers. The obtained Eb/N0 values range from 10 dB to 76 dB at n=2, while throughput varies between 68.5 bps and 270 Mbps depending on distance, activity, and orientation. High Eb/N0 values observed under severe fading conditions are shown to be impractical under realistic power and energy constraints. The results indicate that transmission distance is the dominant performance factor in static scenarios, whereas sensor placement becomes more important under dynamic conditions. In general, chest mounted sensors outperform wrist mounted sensors due to reduced body shadowing in the first case. Furthermore, the use of equal gain combining (EGC) is shown to overcome mobility induced performance degradation for chest mounted nodes, enabling reliable support of a 1 Mbps data rate in all considered scenarios considering the chest as the Tx. Robustness analysis under obstructed indoor propagation (n = 3.5) confirms that although absolute throughput decreases with higher path loss, the relative performance ranking between placement and mobility scenarios remains unchanged. These findings provide quantitative design guidance for reliable and energy efficient MBAN deployment in indoor healthcare environments.Keywords
Funding Information
- Arab Academy for Science, Technology and Maritime Transport
This publication has 27 references indexed in Scilit:
- Enhancement of off-body communications with a low-SAR, high-gain multiband patch antenna designed with a quad-band artificial magnetic conductorInternational Journal of Microwave and Wireless Technologies, 2023
- Comprehensive performance evaluation of on-body communications in MBANs for different node positions in static and dynamic channel conditionsJournal of Electromagnetic Waves and Applications, 2020
- Comprehensive Performance Analysis of Fully Cooperative Communication in WBANsIEEE Access, 2016
- BER performance and data throughput of body sensor networks for reliable biological signal transmission over the human bodyJournal of Electromagnetic Waves and Applications, 2015
- An ultra-wideband wireless body area network: Evaluation in static and dynamic channel conditionsSensors and Actuators A: Physical, 2012
- A Comprehensive Survey of Wireless Body Area NetworksJournal of Medical Systems, 2010
- Wireless Propagation and Coexistence of Medical Body Sensor Networks for Ambulatory Patient Monitoring2009
- Wireless Communications2005
- Reliable Set-Up of Medical Body-Sensor Networks2004
- Digital Communication Over Fading Channels2002