Quality of life and healthcare utilisation improvements after atrial fibrillation ablation
Open Access
Abstract
Objective: Pulmonary vein isolation (PVI) guided by a standardised CLOSE (contiguous optimised lesions) protocol has been shown to increase clinical success after catheter ablation for paroxysmal atrial fibrillation (PAF). This study analysed healthcare utilisation and quality of life (QOL) outcomes from a large multicentre prospective study, measured association between QOL and atrial fibrillation (AF) burden and identified factors associated with lack of QOL improvement.Methods: CLOSE-guided ablation was performed in 329 consecutive patients (age 61.4 years, 60.8% male) with drug-refractory PAF in 17 European centres. QOL was measured at baseline and 12 months post-ablation via Atrial Fibrillation Effect on QualiTy of Life Survey (AFEQT) and EuroQoL EQ-5D-5L questionnaires. All-cause and cardiovascular hospitalisations and cardioversions over 12 months pre-ablation and post-ablation were recorded. Rhythm monitoring included weekly and symptom-driven trans-telephonic monitoring, plus ECG and Holter monitoring at 3, 6 and 12 months. AF burden was defined as the percentage of postblanking tracings with an atrial tachyarrhythmia ≥30 s. Continuous measures across multiple time points were analysed using paired t-tests, and associations between various continuous measures were analysed using independent sample t-tests. Each statistical test used two-sided p values with a significance level of 0.05.Results: Both QOL instruments showed significant 12-month improvements across all domains: AFEQT score increased 25.1–37.5 points and 33.3%–50.8% fewer patients reporting any problem across EuroQoL EQ-5D-5L domains. Overall, AFEQT improvement was highly associated with AF burden (p=0.009 for 2DS2-VASc scores at baseline, and higher AF burden following PVI.Conclusions: QOL improved and healthcare utilisation decreased significantly after ablation with a standardised CLOSE protocol. QOL improvement was significantly associated with impairment at baseline and AF burden after ablation.Trial registration number: NCT03062046.Keywords
Funding Information
- Biosense Webster (N/A)
This publication has 18 references indexed in Scilit:
- Role of Contact Force Sensing in Catheter Ablation of Cardiac ArrhythmiasJACC: Clinical Electrophysiology, 2018
- Catheter Ablation for Atrial Fibrillation with Heart FailureThe New England journal of medicine, 2018
- Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocolEP Europace, 2018
- Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summaryHeart Rhythm, 2017
- The Impact of Cryoballoon Versus Radiofrequency Ablation for Paroxysmal Atrial Fibrillation on Healthcare Utilization and Costs: An Economic Analysis From the FIRE AND ICE TrialJournal of the American Heart Association, 2017
- Poor scar formation after ablation is associated with atrial fibrillation recurrenceJournal of Interventional Cardiac Electrophysiology, 2015
- Estimation of Total Incremental Health Care Costs in Patients With Atrial Fibrillation in the United StatesCirculation: Cardiovascular Quality and Outcomes, 2011
- Development and preliminary testing of the new five-level version of EQ-5D (EQ-5D-5L)Quality of Life Research, 2011
- Development and Validation of the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) Questionnaire in Patients With Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2011