Optimal Generation of Ten Individual Green-to-Red Raman Source for Wavelength-Dependent Real-Time OR-PAM Images
- 13 September 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-9
Abstract
In this study, ten individual green-to-red stimulated Raman scattering (SRS) peaks are optimally generated for wavelength-dependent real-time optical-resolution photoacoustic microscopy (OR-PAM) with contrast agents. Exogenous contrast agents, such as dyes, semiconducting polymers, and metallic nanoparticles, are frequently used in OR-PAM to provide structural, functional, and molecular images of biological samples with a high spatial resolution. For an effective use of various exogenous contrast agents for functional or molecular OR-PAM, selectable visible and near-infrared wavelengths are needed to select the absorption wavelengths of the contrast agents. Therefore, we optimized an SRS source, which can selectively generate ten narrow-band SRS peaks with a bandwidth smaller than 11 nm and individually produce sufficient threshold pulse energies (116-756 nJ) at a high pulse repetition rate (PRR) of 300 kHz. The wavelength-dependent photoacoustic signal was easily obtained in a methylene blue phantom and in vivo mouse studies using the optimal generation conditions of the ten-wavelength green-to-red SRS source, from 545 to 695 nm. In particular, for the first time, wavelength-dependent real-time in vivo OR-PAM images at a PRR of hundreds of kilohertz were obtained to distinguish gold nanoparticles from distributed blood vessels of a mouse ear.Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Science and ICT, Republic of Korea (2017R1A4A1015627)
- Global Ph.D. Fellowship Program (2017H1A2A1043185)
- Civil & Military Technology Cooperation Program, Republic of Korea (16-CM-SS-09)
- Nano Material Technology Development Program (2014M3A7B6020163)
- Creative Materials Discovery Program (2018M3D1A1058814)
- Development of Platform Technology for Innovative Medical Measurement Program (KRISS-2016-16011064)
This publication has 36 references indexed in Scilit:
- Continuous real-time photoacoustic demodulation via field programmable gate array for dynamic imaging of zebrafish cardiac cycleBiomedical Optics Express, 2013
- Wide-field fast-scanning photoacoustic microscopy based on a water-immersible MEMS scanning mirrorJournal of Biomedical Optics, 2012
- Photoacoustic Tomography: In Vivo Imaging from Organelles to OrgansScience, 2012
- Photoacoustic imaging in cancer detection, diagnosis, and treatment guidanceTrends in Biotechnology, 2011
- Enhanced thermal stability of silica-coated gold nanorods for photoacoustic imaging and image-guided therapyOptics Express, 2010
- Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivoJournal of Biomedical Optics, 2009
- Multiwavelength Photoacoustic Imaging and Plasmon Resonance Coupling of Gold Nanoparticles for Selective Detection of CancerNano Letters, 2009
- Functional transcranial brain imaging by optical-resolution photoacoustic microscopyJournal of Biomedical Optics, 2009
- Noninvasive photoacoustic identification of sentinel lymph nodes containing methylene blue in vivo in a rat modelJournal of Biomedical Optics, 2008
- Development of the stimulated Raman spectrum in single-mode silica fibersJournal of the Optical Society of America B, 1984