A Phantom Investigation to Quantify Huygens Principle Based Microwave Imaging for Bone Lesion Detection
Open Access
- 9 December 2019
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 8 (12) , 1505
Abstract
This paper demonstrates the outcomes of a feasibility study of a microwave imaging procedure based on the Huygens principle for bone lesion detection. This study has been performed using a dedicated phantom and validated through measurements in the frequency range of 1–3 GHz using one receiving and one transmitting antenna in free space. Specifically, a multilayered bone phantom, which is comprised of cortical bone and bone marrow layers, was fabricated. The identification of the lesion’s presence in different bone layers was performed on images that were derived after processing through Huygens’ principle, the S21 signals measured inside an anechoic chamber in multi-bistatic fashion. The quantification of the obtained images was carried out by introducing parameters such as the resolution and signal-to-clutter ratio (SCR). The impact of different frequencies and bandwidths (in the 1–3 GHz range) in lesion detection was investigated. The findings showed that the frequency range of 1.5–2.5 GHz offered the best resolution (1.1 cm) and SCR (2.22 on a linear scale). Subtraction between S21 obtained using two slightly displaced transmitting positions was employed to remove the artefacts; the best artefact removal was obtained when the spatial displacement was approximately of the same magnitude as the dimension of the lesion.Keywords
Funding Information
- Horizon 2020 Framework Programme (793449)
This publication has 26 references indexed in Scilit:
- Hardware Implementation of Bone Fracture Detector Using Fuzzy Method Along with Local Normalization TechniqueAnnals of Data Science, 2017
- Time-Domain Multistatic Radar System for Microwave Breast ScreeningIEEE Antennas and Wireless Propagation Letters, 2013
- 3D Microwave bone imaging2012
- Radiation exposure from medical imaging: A silent harm?Canadian Medical Association Journal, 2011
- A Sparsity Regularization Approach to the Electromagnetic Inverse Scattering ProblemIEEE Transactions on Antennas and Propagation, 2009
- An overview of ultra-wideband microwave imaging via space-time beamforming for early-stage breast-cancer detectionIEEE Antennas and Propagation Magazine, 2005
- UWB radars in medicineIEEE Aerospace and Electronic Systems Magazine, 2002
- Current Methods in Medical Image SegmentationAnnual Review of Biomedical Engineering, 2000
- Nonactive antenna compensation for fixed-array microwave imaging. II. Imaging resultsIEEE Transactions on Medical Imaging, 1999
- Microwave power absorption differences between normal and malignant tissueInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1980