Accuracy of CT Perfusion–Based Core Estimation of Follow-up Infarction

Authors:

Abstract
Background and Objectives To assess the accuracy of baseline CT perfusion (CTP) ischemic core estimates. Methods From SELECT (Optimizing Patient Selection for Endovascular Treatment in Acute Ischemic Stroke), a prospective multicenter cohort study of imaging selection, patients undergoing endovascular thrombectomy who achieved complete reperfusion (modified Thrombolysis In Cerebral Ischemia score 3) and had follow-up diffusion-weighted imaging (DWI) available were evaluated. Follow-up DWI lesions were coregistered to baseline CTP. The difference between baseline CTP core (relative cerebral blood flow [rCBF] p = 0.049), 90–270 minutes 0.63 (p < 0.0001), >270 minutes 0.86 (p < 0.0001). Assessment of the spatial overlap between baseline CTP ischemic core lesion and follow-up infarct demonstrated that a median of 3.2 (0.0–9.0) mL of estimated core fell outside the subsequent infarct. These regions were predominantly in white matter. Discussion Significant overestimation of irreversibly injured ischemic core volume was rare, was only observed in patients who presented within 90 minutes of LKW and achieved reperfusion within 120 minutes of CTP acquisition, and occurred primarily in white matter. Use of a more conservative (rCBF <20%) threshold for estimating ischemic core in patients presenting within 90 minutes eliminated all significant overestimation cases. Trial Registration Information ClinicalTrials.gov: NCT03876457.

This publication has 45 references indexed in Scilit: