Comparison of 27‐gauge (0.41‐mm) Whitacre and Quincke spinal needles with respect to post‐dural puncture headache and non‐dural puncture headache
Authors:
- 25 February 2004
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 48 (4) , 474-479
Abstract
Background: The incidence of headache after spinal anaesthesia has varied greatly between studies. We compared the incidence of postoperative headache in general and postdural puncture headache (PDPH) when using 27‐gauge (G) (outer diameter 0.41 mm) Quincke and Whitacre spinal needles in ambulatory surgery performed under spinal anaesthesia.Methods: In a prospective, randomized study, 676 ASA physical status I–II day‐case outpatients were given a spinal anaesthetic through either a 27‐G (0.41 mm) Quincke or a 27‐G (0.41 mm) Whitacre spinal needle. The incidence of any type of postoperative headache was assessed and the type of headache defined using a standardized questionnaire including PDPH criteria. The severity of the headache was defined using a 100‐mm visual analogue scale.Results: For the final analysis, 529 patients were available (259 patients in the Quincke group and 270 patients in the Whitacre group). The overall incidence of postoperative headache was 20.0%, but the incidence of true PDPH was very low (1.51%). The incidence of PDPH in the Quincke group was 2.70%, while in the Whitacre group it was only 0.37% (P < 0.05). The overall incidence of non‐dural puncture headache was 18.5% and did not differ between the study groups.Conclusions: True PDPH seldom occurs when a 27‐G (0.41 mm) spinal needle is used, although postoperatively a non‐specific headache is common. Using the 27‐G (0.41 mm) Whitacre spinal needle further reduced the incidence of PDPH. Thus, we recommend routine use of the 27‐G (0.41 mm) Whitacre spinal needle when performing spinal anaesthesia.Keywords
This publication has 28 references indexed in Scilit:
- Role of needle gauge and tip configuration in the production of lumbar puncture headacheRegional Anesthesia & Pain Medicine, 1997
- Clinical characteristics of commonly used spinal needlesAnaesthesia, 1995
- Postdural Puncture Headache and Spinal Needle DesignAnesthesiology, 1994
- Spinal anaesthesia with 29 gauge Quincke point needles and post dural puncture headache in 2,378 patientsActa Anaesthesiologica Scandinavica, 1994
- The Use of Quincke and Whitacre 27-Gauge Needles in Orthopedic PatientsAnesthesia & Analgesia, 1994
- Headache After Spinal Anesthesia for Cesarean SectionAnesthesia & Analgesia, 1992
- Intrathecal anaesthesia for day‐care surgery A retrospective study of 160 cases using 25‐ and 26‐gauge spinal needlesAnaesthesia, 1990
- Sprotte needle for intrathecal anaesthesia for Caesarean section: incidence of postdural puncture headacheAnaesthesia, 1990
- Post‐dural puncture headache in young patients. A comparative study between the use of 0.52 mm (25‐gauge) and 0.33 mm (29‐gauge) spinal needlesActa Anaesthesiologica Scandinavica, 1990
- Postdural puncture headache A comparison between 26‐ and 29‐gauge needles in young patientsAnaesthesia, 1989