Effect of Cable Length on Time Domain Reflectometry Calibration for High Surface Area Soils
Author:
- 1 January 2000
- journal article
- Published by Wiley in Soil Science Society of America Journal
- Vol. 64 (1) , 54-61
Abstract
Time domain reflectometry (TDR) has been used by soil scientists to determine soil water content (θ). A waveform analysis determines an apparent dielectric number (ϵ a ) which can often be empirically related to ϵ. “Bound water” near colloid surfaces has different properties than free water. At the gigahertz frequencies used for TDR, free water has a negative temperature effect but bound water has a positive temperature effect on dielectric number. Long coaxial cables reduce the higher frequencies of the TDR equipment, which can influence the frequency dependent ϵ a of bound water. The objective of this study was to determine the effect of coaxial cable length and temperature on apparent dielectric properties for samples with and without large amounts of bound water. Two undisturbed columns of Okoboji mucky silty clay loam (fine, smectitic, mesic cumulic Endoaquoll) with a specific surface area of 286 m 2 g −1 and two packed sand samples with calculated surface areas of 0.01 m 2 g −1 were used for the experiment. The ϵ a was determined at four cable length combinations, three temperatures, and a range of θ. The temperature correction factors for Okoboji ranged from 0.008 to 0.012 θ/°C, depending on cable length. Long cables increased the rise time 41%, which decreased the frequency bandwidth. The Okoboji samples had a bulk electrical conductivity as high as 0.14 S m −1 , which hampered determination of the final part of the waveform. In summary for Okoboji, cable length and temperature had a greater effect on ϵ a than did θ. High surface area samples should be calibrated using the same cable length used for measurements, and the temperature effect should be incorporated.Keywords
This publication has 32 references indexed in Scilit:
- Temperature effects on soil bulk dielectric permittivity measured by time domain reflectometry: A physical modelWater Resources Research, 1999
- Temperature effects on soil bulk dielectric permittivity measured by time domain reflectometry: Experimental evidence and hypothesis developmentWater Resources Research, 1999
- Electrical properties of water in clay and silty soilsJournal of Applied Geophysics, 1998
- Texture and Electrical Conductivity Effects on Temperature Dependency in Time Domain ReflectometrySoil Science Society of America Journal, 1998
- Calibration of time domain reflectometry technique using undisturbed soil samples from humid tropical soils of volcanic originWater Resources Research, 1997
- Errors in Converting Time Domain Reflectometry Measurements of Propagation Velocity to Estimates of Soil Water ContentSoil Science Society of America Journal, 1996
- Frequency domain analysis of time domain reflectometry waveforms: 1. Measurement of the complex dielectric permittivity of soilsWater Resources Research, 1994
- Design of Triple‐Wire Time Domain Reflectometry Probes in Practice and TheorySoil Science Society of America Journal, 1993
- Remote Diode Shorting Improves Measurement of Soil Water by Time Domain ReflectometrySoil Science Society of America Journal, 1992
- A method of measuring soil moisture by time-domain reflectometryJournal of Hydrology, 1986