New Computerized Method in Measuring the Sagittal Bowing of Femur from Plain Radiograph—A Validation Study
Open Access
- 3 October 2019
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (10) , 1598
Abstract
Background: Mismatch of intramedullary nails with the bowing of femur is a frequent clinical finding. Previous studies showed inconsistent results. Methods: We present an algorithm of region growing territory method to get the radii of the anterior bowing of femur. We also tested it on ten radiographs. Plain radiographs of the lateral view of femur from five men and five women taken between January and August 2014 in Taipei Hospital were chosen randomly. The curvature of femur outline and medullary canal were measured for three times each. Radii of curvature of whole femur, proximal, middle and distal parts were calculated and analyzed. Results: The coefficient of variation of the 240 measurements ranged from 0.007 to 0.295 and averaged 0.088. The average radii of curvature of the whole, proximal, middle, and distal femur were 1318 mm, 752 mm, 1379 mm, and 599 mm, respectively. At the distal part of the femur, the radius of curvature of the femur outline (452 mm) was smaller than the medullary canal (746 mm) (p < 0.05). Women’s femur was straighter than men’s when we compared the whole length (1435 mm vs. 1201 mm, p < 0.05). The radii we calculated were smaller than the current intramedullary nails. Conclusion: The results showed that the inter-observer and intra-observer differences are acceptable, support the impression that different bowing conditions existed for Asians as compared to Caucasians, and also indicate the mismatch of current instruments to the curvature of femur.Keywords
This publication has 23 references indexed in Scilit:
- Three-Dimensional Computed Tomography–Based Modeling of Sagittal Cadaveric Femoral Bowing and Implications for Intramedullary NailingJournal of Orthopaedic Trauma, 2014
- A region growing method for tumor volume segmentation on PET images for rectal and anal cancer patientsMedical Physics, 2009
- Variances in Sagittal Femoral Shaft Bowing in Patients Undergoing TKAClinical Orthopaedics and Related Research, 2008
- The comparison of femoral curves and curves of contemporary intramedullary nailsSurgical and Radiologic Anatomy, 2005
- Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplastyJournal of Orthopaedic Research, 2005
- Complications following the treatment of trochanteric fractures with the gamma nailArchives of orthopaedic and trauma surgery, 2004
- Mismatch of Current Intramedullary Nails With the Anterior Bow of the FemurJournal of Orthopaedic Trauma, 2004
- Temporal trends in femoral curvature and length in medieval and modern ScotlandAmerican Journal of Physical Anthropology, 2002
- Multiresolution shape representation without bordershiftingElectronics Letters, 1999
- Geometric Mismatch of the Gamma Nail to the Chinese FemurClinical Orthopaedics and Related Research, 1996