Isotropic submillimeter fMRI in the human brain at 7 T: Combining reduced field‐of‐view imaging and partially parallel acquisitions
Open Access
- 9 January 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (5) , 1506-1516
Abstract
Echo‐planar imaging is the most widely used imaging sequence for functional magnetic resonance imaging (fMRI) due to its fast acquisition. However, it is prone to local distortions, image blurring, and signal voids. As these effects scale with echo train length and field strength, it is essential for high‐resolution echo‐planar imaging at ultrahigh field to address these problems. Partially parallel acquisition methods can be used to improve the image quality of echo‐planar imaging. However, partially parallel acquisition can be affected by aliasing artifacts and noise enhancement. Another way to shorten the echo train length is to reduce the field‐of‐view (FOV) while maintaining the same spatial resolution. However, to achieve significant acceleration, the resulting FOV becomes very small. Another problem occurs when FOV selection is incomplete such that there is remaining signal aliased from the region outside the reduced FOV. In this article, a novel approach, a combination of reduced FOV imaging with partially parallel acquisition, is presented. This approach can address the problems described above of each individual method, enabling high‐quality single‐shot echo‐planar imaging acquisition, with submillimeter isotropic resolution and good signal‐to‐noise ratio, for fMRI at ultrahigh field strength. This is demonstrated in fMRI of human brain at 7T with an isotropic resolution of 650 μm. Magn Reson Med, 2012.Keywords
This publication has 24 references indexed in Scilit:
- Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1NeuroImage, 2010
- Isotropic Sub-Millimeter fMRI of V5 in Human at 7TNeuroImage, 2009
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- High resolution single-shot EPI at 7TMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The Effect of Slice Order and Thickness on fMRI Activation Data Using Multislice Echo-Planar ImagingNeuroImage, 1999
- Single‐shot localized echo‐planar imaging (STEAM‐EPI) at 4.7 teslaMagnetic Resonance in Medicine, 1990
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Zonally magnified EPI in real time by NMRJournal of Physics E: Scientific Instruments, 1988