Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
Authors:
Open Access
- 1 January 2018
- journal article
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 10 (11) , e1096-e1102
Abstract
Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions using full-arch versus sectional tray and Vinyl Polysiloxane versus Vinyl Polyether Siloxane in angulated implants. Four implants were placed in dental areas #19, #21, #28 and #30 of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty sectional and 20 full-arch open trays were made on the primary cast. Impressions were taken using Vinyl Polysiloxane and Vinyl Polyether Siloxane (n=10 in 4 groups); and were poured with type IV dental stone. The coordinate measuring machine was used to measure displacements in the X, Y and Z axes and rotational discrepancies of implants. The data were analyzed using SPSS 22 and two-way ANOVA. Type of tray had no significant effect on the dimensional and angular accuracy of impressions (p >0.05). Type of impression material significantly affected linear displacement (∆r) (P 0.05). Vinyl Polysiloxane yielded more accurate impressions of angulated implants. Key words:Dental implant, impression material, impression tray, vinyl polysiloxane, vinyl polyether silicone, coordinate measuring machine.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy of 3 different impression techniques for internal connection angulated implantsThe Journal of Prosthetic Dentistry, 2015
- Digital evaluation of the accuracy of impression techniques and materials in angulated implantsJournal of Dentistry, 2014
- An In Vitro Evaluation of Impression Techniques for Multiple Internal- and External-Connection Implant ProsthesesThe International Journal of Oral and Maxillofacial Implants, 2014
- Effects of impression levels and trays on the accuracy of impressions taken from angulated implantsClinical Oral Implants Research, 2014
- Comparative Evaluation of the Effects of Implant Position, Impression Material, and Tray Type on Implant Impression AccuracyImplant Dentistry, 2014
- The Effect of Implant Connection Length on the Dimensional Impression Accuracy of Inclined ImplantsThe International Journal of Oral and Maxillofacial Implants, 2013
- The effect of impression technique and implant angulation on the impression accuracy of external- and internal-connection implants.2012
- Effect of Implant Angulation, Connection Length, and Impression Material on the Dimensional Accuracy of Implant Impressions: An In Vitro Comparative StudyClinical Implant Dentistry and Related Research, 2010
- The accuracy of implant impressions: A systematic reviewThe Journal of Prosthetic Dentistry, 2008
- Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro studyThe Journal of Prosthetic Dentistry, 2008