Global Endometrial Ablation for Menorrhagia in Women With Bleeding Disorders
Authors:
- Sherif A. El-NasharSESherif A. El-Nashar
- Matthew R. HopkinsMHMatthew R. Hopkins
- Simone S. FeitozaSFSimone S. Feitoza
- Rajiv K. PruthiRPRajiv K. Pruthi
- Sunni A. BarnesSBSunni A. Barnes
- John B. GebhartJGJohn B. Gebhart
- William A. ClibyWCWilliam A. Cliby
- Abimbola O. FamuyideAFAbimbola O. Famuyide
- 1 June 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 109 (6) , 1381-1387
Abstract
To evaluate the efficacy of global endometrial ablation in women with bleeding disorders who presented with menorrhagia. A records-linkage system was used to construct a retrospective cohort of 41 women with bleeding disorders (coagulopathy) and a reference group of 111 randomly selected women without bleeding disorders from a pool of 943 women who underwent global endometrial ablation (with thermal balloon ablation technology or bipolar radiofrequency ablation technology) for menorrhagia at Mayo Clinic (Rochester, Minnesota) from January 1995 through December 2005. Demographic data, type of global endometrial ablation therapy and reablation, and hysterectomy data were extracted from the database. There was no significant difference in baseline age, parity, body mass index, uterine size, type of global endometrial ablation therapy, or duration of follow-up between the groups. Two women (5%) in the coagulopathy group had hysterectomy or reablation, compared with 8 (7%) in the reference group (Fisher exact test, P=.728). A Kaplan-Meier plot showed no difference in the time to treatment failure between the groups (log-rank test, P=.534). Procedural-related complications were generally minor and infrequent (9 of 152 [6%]). Complications were equally distributed in the coagulopathy (4 of 41) and reference groups (6 of 111) (Fisher exact test, P=.267). Global endometrial ablation is an effective treatment choice for women with coagulopathy presenting with menorrhagia.Keywords
This publication has 19 references indexed in Scilit:
- NovaSure impedance controlled system for endometrial ablation: Three-year follow-up on 107 patientsAmerican Journal of Obstetrics and Gynecology, 2004
- Randomised controlled trial of bipolar radio‐frequency endometrial ablation and balloon endometrial ablationBJOG: An International Journal of Obstetrics & Gynaecology, 2004
- Treatment of menorrhagia in women undergoing hematopoietic stem cell transplantationBone Marrow Transplantation, 2004
- Oral anticoagulation in surgical procedures: risks and recommendationsBritish Journal of Haematology, 2003
- Efficacy of thermal balloon ablation in patients with abnormal uterine bleedingAmerican Journal of Obstetrics and Gynecology, 2003
- Thermal balloon endometrial ablation for management of acute uterine hemorrhageObstetrics & Gynecology, 2002
- Patterns of ambulatory care use for gynecologic conditions: A national studyAmerican Journal of Obstetrics and Gynecology, 2001
- Emergency Endometrial Resection in Women with Acute, Severe Uterine BleedingThe Journal of the American Association of Gynecologic Laparoscopists, 2000
- Emergency endometrial ablation for life-threatening uterine bleeding as a result of a coagulopathyThe Journal of the American Association of Gynecologic Laparoscopists, 1998
- Management of abnormal uterine bleedingAmerican Journal of Obstetrics and Gynecology, 1996