Distal plate fracture as a novel complication following TTA surgery in two dogs
Authors:
- 1 October 2018
- journal article
- research article
- Published by Wiley in Veterinary Record Case Reports
- Vol. 6 (4) , e000695
Abstract
Two Rottweilers with cranial cruciate ligament (CCL) disease were referred for evaluation and treatment. Both patients underwent radiographs and examination under sedation, which confirmed CCL disease. Arthrotomy of the affected stifles revealed a partial CCL rupture in one patient and a complete CCL rupture in the other patient. The two patients underwent tibial tuberosity advancement (TTA) for treatment. In both cases, the TTA plate broke and the patients underwent a second operation to replace the broken plate. One patient was lost to follow‐up after the second operation, while the other had acceptable function of the leg. Metallurgical analysis of the explanted plate in the second patient revealed corrosion as the predominant mechanism of plate failure. Despite the inherent resistance to corrosion presented by titanium implants, it is still possible for corrosion to lead to implant failure. However, replacement of the failed implant could lead to full recovery.Keywords
This publication has 29 references indexed in Scilit:
- The Effect of Cancellous Autograft and Novel Plate Design on Radiographic Healing and Postoperative Complications in Tibial Tuberosity Advancement for Cranial Cruciate‐Deficient Canine StiflesVeterinary Surgery, 2011
- Tibial tuberosity advancement in 92 canine stifles: initial results, clinical outcome and owner evaluationAustralian Veterinary Journal, 2010
- Biomedical Implants: Corrosion and its Prevention - A ReviewRecent Patents on Corrosion Science, 2010
- Short‐term and eight to 12 months results of a tibial tuberosity advancement as treatment of canine cranial cruciate ligament damageJournal of Small Animal Practice, 2008
- Tibial Tuberosity Advancement for Stabilization of the Canine Cranial Cruciate Ligament‐Deficient Stifle Joint: Surgical Technique, Early Results, and Complications in 101 DogsVeterinary Surgery, 2007
- Crevice Corrosion of Implants Recovered After Tibial Plateau Leveling Osteotomy in DogsVeterinary Surgery, 2006
- Failure analysis of a commercially pure titanium plate for osteosynthesisEngineering Failure Analysis, 2003
- The repair of humeral condylar fractures in the dog: a review of seventy‐nine casesJournal of Small Animal Practice, 1985
- Triceps tendon rupture in the dog following corticosteroid injectionJournal of Small Animal Practice, 1982
- Self-colour anodizing of titaniumSurface Technology, 1982