Analysis of electrical interferences related to the current collection quality in pantograph–catenary interaction
Authors:
- G BuccaG Bucca
- A CollinaACA Collina
- R ManigrassoRMR Manigrasso
- F MapelliFMF Mapelli
- D TarsitanoD Tarsitano
- 19 August 2011
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
- Vol. 225 (5) , 483-500
Abstract
The dynamic interaction between a pantograph and a catenary influences the quality of the current collection; in particular, when two pantographs are used to collect current, the second pantograph is subjected to the disturbances originated on the overhead line by the transit of the first pantograph, generally causing a deterioration of current collection quality. Under these conditions, the occurrence of continuous sparking, contact loss, and arcing cause an increase of wear for both contact wire and collector strips, but also cause variations of contact voltage and feed current that in turn produce interferences on the on-board electrical systems like drive motors and signalling system. In order to investigate the latter, a procedure for the correlation of the quality of current collection with the level of electrical interference is proposed in this article. The procedure is based on experimental and numerical models combining relationships obtained by means of laboratory tests with simulation tools. An application to a real case of double pantograph collection is presented.Keywords
This publication has 7 references indexed in Scilit:
- In situ graphite lubrication of metallic sliding electrical contactsWear, 2009
- A procedure for the wear prediction of collector strip and contact wire in pantograph–catenary systemWear, 2009
- Wear of pantograph collector stripsProceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 2008
- DC components in pantograph arcing: mechanisms and influence of various parameters2007
- Impact of overhead line irregularity on current collection and diagnostics based on the measurement of pantograph dynamicsProceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 2007
- Numerical Simulation of Pantograph-Overhead Equipment InteractionVehicle System Dynamics, 2002
- Effect of arc discharge on wear rate of Cu-impregnated carbon strip in unlubricated sliding against Cu trolley under electric currentWear, 1998