Mass Flow Rate Measurement of Oil-Water Two-Phase Flow by a Long-Waist Cone Meter
Authors:
- 18 June 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (10) , 2795-2804
Abstract
A long-waist cone meter is proposed for horizontal oil-water two-phase flow rate measurement. A constricting differential pressure Δp and an overall differential pressure δp were tapped for flow rate measurement. Δp is related to flow rate through Bernoulli's equation. A correlation for predicting the mass flow rate by using the overall differential pressure δp is presented through physical analysis. Correlations of Δp and δp are then extended to predict the mass flow rate of two-phase flow based on the separated flow model. A dual differential pressure model is then proposed by combining the two correlations of Δptp and δptp. The flow regimes in the experiments include water continuous and oil continuous. Prediction on overall mass flow rate is improved by using the dual differential pressure model at an associated error of 2.7% and 4.1%, respectively, for water-continuous flow and oil-continuous flow. This paper indicates that the overall mass flow rate of oil-water two-phase flow can be determined at an accuracy within ±5% with a long-waist cone meter and the dual differential pressure models without the aid of a secondary instrument for the phase fraction measurement, and the results are less affected by phase inversion.Keywords
This publication has 22 references indexed in Scilit:
- Experimental and numerical design of a long-waist cone flow meterSensors and Actuators A: Physical, 2013
- Wet gas flow modeling for a vertically mounted Venturi meterMeasurement Science and Technology, 2012
- Investigation on pressure-tapping methods of long waist cone flow meter using CFD simulationAIP Conference Proceedings, 2012
- Discharge coefficient performance of Venturi, standard concentric orifice plate, V-cone and wedge flow meters at low Reynolds numbersJournal of Petroleum Science and Engineering, 2011
- High GVF and low pressure gas–liquid two-phase flow measurement based on dual-cone flowmeterFlow Measurement and Instrumentation, 2010
- CFD prediction of the effects of the upstream elbow fittings on the performance of cone flowmetersFlow Measurement and Instrumentation, 2010
- Study on wet gas online flow rate measurement based on dual slotted orifice plateFlow Measurement and Instrumentation, 2009
- Investigation of the mixture flow rates of oil-water two-phase flow using the turbine flow meterJournal of Physics: Conference Series, 2009
- Investigation of oil-air two-phase mass flow rate measurement using Venturi and void fraction sensorJournal of Zhejiang University-SCIENCE A, 2005
- Flow Measurement Handbook2000