Evaluation of temperature increase during in-office bleaching
Open Access
- 1 April 2016
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 24 (2) , 136-141
Abstract
The use of light sources in the bleaching process reduces the time required and promotes satisfactory results. However, these light sources can cause an increase in the pulp temperature. Objective The purpose of the present study was to measure the increase in intrapulpal temperature induced by different light-activated bleaching procedures with and without the use of a bleaching gel. Material and Methods A human maxillary central incisor was sectioned 2 mm below the cementoenamel junction. A K-type thermocouple probe was introduced into the pulp chamber. A 35% hydrogen peroxide bleaching gel was applied to the vestibular tooth surface. The light units used were a conventional halogen, a hybrid light (only LED and LED/Laser), a high intensity LED, and a green LED light. Temperature increase values were compared by two-way ANOVA and Tukey´s tests (p<0.05). Results There were statistically significant differences in temperature increases between the different light sources used and between the same light sources with and without the use of a bleaching gel. The presence of a bleaching gel generated an increase in intra-pulpal temperature in groups activated with halogen light, hybrid light, and high intensity LED. Compared to the other light sources, the conventional halogen lamp applied over the bleaching gel induced a significant increase in temperature (3.83±0.41°C). The green LED unit with and without gel application did not produce any significant intrapulpal temperature variations. Conclusion In the present study, the conventional halogen lamp caused the highest increase in intrapulpal temperature, and the green LED caused the least. There was an increase in temperature with all lights tested and the maximum temperature remained below the critical level (5.5°C). The addition of a bleaching gel led to a higher increase in intrapulpal temperatures.Keywords
This publication has 28 references indexed in Scilit:
- An in vitro thermal analysis during different light-activated hydrogen peroxide bleachingLaser Physics, 2010
- Parameters Influencing Increase in Pulp Chamber Temperature with Light-curing Devices: Curing Lights and Pulpal Flow RatesOperative Dentistry, 2010
- Undesirable and adverse effects of tooth-whitening products: a reviewClinical Oral Investigations, 2009
- Effect of simulated pulpal microcirculation on intrachamber temperature changes following application of various curing units on tooth surfaceJournal of Dentistry, 2009
- A Thermal Investigation of Dental Bleaching In VitroPhotomedicine and Laser Surgery, 2008
- Clinical Evaluation of In-office Dental Bleaching Treatments With and Without the Use of Light-activation SourcesOperative Dentistry, 2008
- Effects of KTP Laser Irradiation, Diode Laser, and LED on Tooth Bleaching: A Comparative StudyPhotomedicine and Laser Surgery, 2007
- Pulpal temperature rise during light‐activated bleachingJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary studyJournal of Oral Rehabilitation, 1997
- Microscopic Observations on Living Dental Pulp II. The Effect of Thermal Irritants on the Circulation of the Pulp in the Lower Rat IncisorActa Odontologica Scandinavica, 1958