Real-Life Value of the Odysight® Application in At-Home Screening for Exudative Recurrence of Macular Edema
Open Access
- 26 August 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (17) , 5010
Abstract
Background: The aim of this study was to describe the value of the Odysight® application in addition to a classical follow-up regimen in the detection of exudative recurrences in patients with macular edema. Methods: We conducted an observational, multicenter, retrospective study. The Odysight® application includes a visual acuity (VA) test that can lead to alerts in case of a drop of >5 VA letters on two successive tests. The efficacy of the alerts in detecting exudative recurrence was studied. Results: A total of 149 eyes of 123 patients were included. The sensitivity of alerts for the detection of recurrence was 30.8% (95% CI [17.6; 44.0]) and its specificity was 83.7% (95% CI [73.2; 94.3]. A better baseline VA was found to be significantly associated with a better retention of the application (OR = 0.05, 95% CI [0.002; 0.62]; p = 0.045). Of the 12/39 alerts that detected a recurrence, eight (20.5% of all alerts) resulted in the scheduling or advancement of an intravitreal injection. Conclusions: In the present study, the sensitivity and positive predictive value of the Odysight® application seems low but its use in addition to the usual follow-up of the patient can detect, in certain cases, an early recurrence and thus allow an anticipated readjustment of the treatment.Keywords
This publication has 25 references indexed in Scilit:
- The Pattern of Recurrence in Diabetic Macular Edema Treated by Dexamethasone Implant: The PREDIAMEX StudyOphthalmology Retina, 2018
- Reproductibilité des mesures de l’acuité visuelle par échelle ETDRS en pratique quotidienneJournal Français d'Ophtalmologie, 2016
- Strategies for improving early detection and diagnosis of neovascular age-related macular degenerationClinical Ophthalmology, 2015
- Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysisEye, 2014
- Randomized trial of the ForeseeHome monitoring device for early detection of neovascular age-related macular degeneration. The HOme Monitoring of the Eye (HOME) study design — HOME Study report number 1Contemporary Clinical Trials, 2014
- FEASIBILITY OF A NOVEL REMOTE DAILY MONITORING SYSTEM FOR AGE-RELATED MACULAR DEGENERATION USING MOBILE HANDHELD DEVICESRetina, 2013
- Incidence of Legal Blindness From Age-Related Macular Degeneration in Denmark: Year 2000 to 2010American Journal of Ophthalmology, 2012
- The Amsler chart is of doubtful value in retinal screening for early laser therapy of subretinal membranes. The West London SurveyEye, 2004
- How Sensitive to Clinical Change are ETDRS logMAR Visual Acuity Measurements?Investigative Ophthalmology & Visual Science, 2003
- Variability of measurements of visual acuity in a large eye clinicActa Ophthalmologica Scandinavica, 1999