Testing and Analysis of Precast Columns with Grouted Sleeve Connections and Shifted Plastic Hinging
- 1 October 2017
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 22 (10)
Abstract
Prefabricated reinforced concrete column connections employing grouted sleeve (GS) splices enable rapid construction, are familiar to contractors, and their detailing resembles cast-in-place (CIP) construction. Previous studies showed disrupted plastic hinge formation in the stiff sleeve region. The proposed design method shifts the plastic hinge location above the sleeve region, which effectively increases the plastic rotation capacity and ductility. Plastic hinge shifting was realized by using transition splicing and high-strength steel reinforcement in the connecting element (footing). The proposed method was investigated experimentally using two 0.42-scale column tests under slow cyclic loading and a series of uniaxial tensile tests. Results indicate that good ductility can be achieved compared with conventional CIP construction and previously tested GS connections details. Experimental and analytical moment-curvature results were used to support discussion of design considerations and of an approximate method for calculating the displacement ductility of precast columns with GS connections and shifted plastic hinging.Keywords
This publication has 15 references indexed in Scilit:
- Shaking Table Performance of a New Bridge System with Pretensioned Rocking ColumnsJournal of Bridge Engineering, 2016
- Plastic Hinge Relocation Methods for Emulative PC Beam–Column ConnectionsJournal of Structural Engineering, 2016
- BEHAVIOR AND SIMPLIFIED MODELING OF MECHANICAL REINFORCING BAR SPLICESACI Structural Journal, 2015
- Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column–to–cap beam joints in accelerated bridge constructionPCI Journal, 2015
- Repair of Reinforced Concrete Bridge Columns Containing Buckled and Fractured Reinforcement by Plastic Hinge RelocationJournal of Bridge Engineering, 2014
- Seismic Performance of Precast Columns with Mechanically Spliced Column-Footing ConnectionsACI Structural Journal, 2014
- Seismic Resistance of Socket Connection between Footing and Precast ColumnJournal of Bridge Engineering, 2013
- Behaviour of grouted pipe splice under incremental tensile loadConstruction and Building Materials, 2012
- Grout-Filled Pipe Splices for Precast Concrete ConstructionPCI Journal, 1995
- Theoretical Stress‐Strain Model for Confined ConcreteJournal of Structural Engineering, 1988