A microchannel-plate photomultiplier (MCP-PMT) has been applied to the time-correlated single-photon counting technique. Electrical and timing characteristics were investigated for the two types of MCP-PMT’s, nonproximity type (Hamamatsu R1264) and proximity type (R1564), which are different in distance between the photocathode and MCP. In the proximity type, the transit-time spread was found to be 60 ps, i.e., a factor of 4 shorter than that in conventional photomultipliers with a dynode string. It was concluded that both types of MCP-PMT’s are fully applicable to the single-photon counting method and that the proximity type MCP-PMT in particular leads to further improvements in the cathode transit-time difference and the wavelength effect of the timing properties. Some examples of experimental results are shown for fluorescence decay curves and picosecond time-resolved spectra.Keywords
This publication has 14 references indexed in Scilit:
- EXCITATION ENERGY TRANSFER IN THE LIGHT HARVESTING ANTENNA SYSTEM OF THE RED ALGAPorphyridium cruentumAND THE BLUE‐GREEN ALGAAnacystis nidulans: ANALYSIS OF TIME‐RESOLVED FLUORESCENCE SPECTRAPhotochemistry and Photobiology, 1984
- Intramolecular electronic relaxation and photoisomerization processes in the isolated azabenzene molecules pyridine, pyrazine and pyrimidineFaraday Discussions of the Chemical Society, 1983
- Applicability of a microchannel plate photomultiplier to the time-correlated photon counting techniqueApplied Optics, 1982
- Subnanosecond fluorescence lifetimes of pyrazine-h4 and -d4 vapor for photoselected vibrational levels in the S1(n, π*) stateChemical Physics Letters, 1982
- Subnanosecond fluorescence-lifetime measuring system using single photon counting method with mode-locked laser excitationReview of Scientific Instruments, 1981
- Photophysics of aqueous tryptophan: pH and temperature effectsJournal of the American Chemical Society, 1980
- Improved timing resolution in time-correlated photon counting spectrometry with a static crossed-field photomultiplierAnalytical Chemistry, 1979
- Subnanosecond single photon counting fluorescence spectroscopy using synchronously pumped tunable dye laser excitationReview of Scientific Instruments, 1978
- Picosecond fluorescence studies of xanthene dyesJournal of the American Chemical Society, 1977
- Confidence in fluorescence lifetime determinations: a ratio correction for the photomultiplier time response with wavelengthCanadian Journal of Chemistry, 1976