Quantitative analysis of terpenoids in the gas phase using headspace solid‐phase microextraction (HS‐SPME)
Authors:
- 28 August 2001
- journal article
- research article
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 16 (6) , 411-416
Abstract
A relationship between the fibre coating/gas phase partition coefficient (Kfg) of terpenoids and their linear temperature programmed retention index (LTPRI) was derived using a group of selected monoterpenoids (with LTPRI's ≤ 1124). The accuracy of this relationship was tested by comparing calculated and experimentally measured Kfg values for the same group of 13 compounds, including monoterpene hydrocarbons, alcohols and ethers. A good agreement between the two values (RSD ≤ 11%) was found for most compounds, even when a BPX‐5 GC column was used for the determination of the LTPRI values. The derived model was then applied to the prediction of Kfg values for 37 other terpenoids found in aromatic plants. The similarity between calculated and experimentally measured Kfg values was found to be acceptable, even when the model was extrapolated for compounds with LTPRIs as high as 1481. Some of the predicted values were then applied to the quantitative determination of damage‐induced changes in the headspace concentration above Salvia officinalis L. (common sage) leaves. The relationship established in this paper enables the simple and accurate determination of terpenoids in the gas phase, using polydimethylsiloxane–solid‐phase microextraction (PDMS–SPME) at 25 °C. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Considerations on Static and Dynamic Sorptive and Adsorptive Sampling to Monitor Volatiles Emitted by Living PlantsJournal of High Resolution Chromatography, 2000
- Solid-phase microextraction: a promising technique for sample preparation in environmental analysisJournal of Chromatography A, 2000
- Dynamic Headspace Analysis of Floral Volatiles: A Comparison of MethodsOikos, 1998
- The effect of sample volume on quantitative analysis by solid phase microextraction Part 2.† Experimental verificationThe Analyst, 1998
- Estimation of Air/Coating Distribution Coefficients for Solid Phase Microextraction Using Retention Indexes from Linear Temperature-Programmed Capillary Gas Chromatography. Application to the Sampling and Analysis of Total Petroleum Hydrocarbons in AirAnalytical Chemistry, 1997
- Effect of Sample Volume on Quantitative Analysis by Solid-phase MicroextractionPart 1. Theoretical ConsiderationsThe Analyst, 1997
- Determination of Essential Oils in Hops by Headspace Solid-Phase MicroextractionJournal of Agricultural and Food Chemistry, 1996
- Analysis of monoterpenes from conifer needles using solid phase microextractionJournal of High Resolution Chromatography, 1995
- Dynamics of organic compound extraction from water using liquid-coated fused silica fibersAnalytical Chemistry, 1992
- Solid phase microextraction with thermal desorption using fused silica optical fibersAnalytical Chemistry, 1990