Technetium-99m-labeled genistein as a potential radical scavenging agent
Authors:
Open Access
- 1 January 2019
- journal article
- research article
- Published by Medknow in Journal of Advanced Pharmaceutical Technology & Research
- Vol. 10 (3) , 112-116
Abstract
The purpose of this study was to determine the optimum conditions for labeling genistein compounds with technetium-99m (99mTc) radionuclides and the percentage of purity obtained in accordance with the requirements of the United State Pharmacopeia. The method used is optimization of several parameters including pH, SnCl2.2H2O as reducing agents, genistein concentration, and incubation time. The results showed that the optimum conditions for labeling 99mTc-Genistein were obtained under conditions of pH 8, the amount of SnCl2.2H2O reducing agents was 30 μg, 0.5 mg genistein, and in 10 min. The optimization of this condition resulted in radiochemical purity in the labeling of 99mTc-Genistein compounds at 95.43% ± 0.85%. The radiochemical purity of the labeling of 99mTc-Genistein compounds has met the requirements of the United State Pharmacopeia as a compound marked for diagnosis of more than 90%.Keywords
This publication has 3 references indexed in Scilit:
- Direct labeling of doxorubicin with technetium-99m: its optimization, characterization and quality controlJournal of Radioanalytical and Nuclear Chemistry, 2012
- Genistein Inhibits Proliferation of Human Endometrial Endothelial Cell in vitroChinese Medical Sciences Journal, 2008
- The use of redox polymers in labelling procedures of proteins and peptides with 99mTc. II. Technique of preparation of kits for protein labelling by 99mTc and its effect on the stability and radiochemical purity.2000