Maximizing Tibial Coverage Is Detrimental to Proper Rotational Alignment
- 1 January 2014
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (1) , 121-125
Abstract
Traditionally, the placement of the tibial component in total knee arthroplasty (TKA) has focused on maximizing coverage of the tibial surface. However, the degree to which maximal coverage affects correct rotational placement of symmetric and asymmetric tibial components has not been well defined and might represent an implant design issue worthy of further inquiry. Using four commercially available tibial components (two symmetric, two asymmetric), we sought to determine (1) the overall amount of malrotation that would occur if components were placed for maximal tibial coverage; and (2) whether the asymmetric designs would result in less malrotation than the symmetric designs when placed for maximal coverage in a computer model using CT reconstructions. CT reconstructions of 30 tibial specimens were used to generate three-dimensional tibia reconstructions with attention to the tibial anatomic axis, the tibial tubercle, and the resected tibial surface. Using strict criteria, four commercially available tibial designs (two symmetric, two asymmetric) were placed on the resected tibial surface. The resulting component rotation was examined. Among all four designs, 70% of all tibial components placed in orientation maximizing fit to resection surface were internally malrotated (average 9°). The asymmetric designs had fewer cases of malrotation (28% and 52% for the two asymmetric designs, 100% and 96% for the two symmetric designs; p < 0.001) and less malrotation on average (2° and 5° for the asymmetric designs, 14° for both symmetric designs; p < 0.001). Maximizing tibial coverage resulted in implant malrotation in a large percentage of cases. Given similar amounts of tibial coverage, correct rotational positioning was more likely to occur with the asymmetric designs. Malrotation of components is an important cause of failure in TKA. Priority should be given to correct tibial rotational positioning. This study suggested that it is easier to balance rotation and coverage with asymmetric tibial baseplates; clinical research will need to determine whether the observed difference affects patellar tracking, loosening rates, or the likelihood of revisions after TKA.Keywords
This publication has 24 references indexed in Scilit:
- The Flexion-Extension Axis of the Knee and its Relationship to the Rotational Orientation of the Tibial PlateauThe Journal of Arthroplasty, 2011
- Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2011
- Biomechanical effects of total knee arthroplasty component malrotation: A computational simulationJournal of Orthopaedic Research, 2011
- Rotational References for Total Knee Arthroplasty Tibial Components Change with Level of ResectionClinical Orthopaedics and Related Research, 2010
- Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial borderBMC Musculoskeletal Disorders, 2010
- Rotational Position of Femoral and Tibial Components in TKA Using the Femoral Transepicondylar AxisClinical Orthopaedics and Related Research, 2008
- Early Revision for Component Malrotation in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- The John Insall Award: Patient Expectations Affect Satisfaction with Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Mechanisms of Failure of the Femoral and Tibial Components in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1989