A 0.8 V, 14.76 nVrms, Multiplexer-Based AFE for Wearable Devices Using 45 nm CMOS Techniques
Open Access
- 23 September 2023
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1816
Abstract
Wearable medical devices (WMDs) that continuously monitor health conditions enable people to stay healthy in everyday situations. A wristband is a monitoring format that can measure bioelectric signals. The main part of a wearable device is its analog front end (AFE). Wearables have issues such as low reliability, high power consumption, and large size. A conventional AFE device uses more analog-to-digital converters, amplifiers, and filters for individual electrodes. Our proposed MUX-based AFE design requires fewer components than a conventional AFE device, reducing power consumption and area. It includes a single-ended differential feedback operational transconductance amplifier (OTA) and n-pass MUX-based AFE circuits which are related to the emergence of low power, low area, and low cost AFE-integrated chips that are required for wearable biomedical applications. The proposed 6T n-pass multiplexer measures a gain of −68 dB across a frequency range of 100 kHz with a 136.5 nW power consumption and a delay of 0.07 ns. The design layout area is approximately 9.8 µm2 and uses 45 nm complementary metal oxide semiconductor (CMOS) technology. Additionally, the proposed single-ended differential OTA has an obtained input referred noise of 0.014 µVrms, and a gain of −5.5 dB, while the design layout area is about 2 µm2 and was designed with the help of the Cadence Virtuoso layout design tool.Keywords
This publication has 49 references indexed in Scilit:
- Multimodal Analog Front End for Wearable Bio-SensorsIEEE Sensors Journal, 2016
- A 0.5-V 1.3- $\mu\text{W}$ Analog Front-End CMOS CircuitIEEE Transactions on Circuits and Systems II: Express Briefs, 2016
- Two new Schmitt trigger circuits based on current sink and current source inverters2015
- Six Order Cascaded Power Line Notch Filter for ECG Detection Systems with Noise ShapingCircuits, Systems, and Signal Processing, 2014
- Low-power low-noise analog signal conditioning chip with on-chip drivers for healthcare applicationsMicroelectronics Journal, 2012
- Design of Optimal Amplifier for Wearable Devices2011
- Analog Integrated Circuits Design for Processing Physiological SignalsIEEE Reviews in Biomedical Engineering, 2010
- A survey on wearable biosensor systems for health monitoring2008
- Heart disease and workHeart, 2004
- SOI technology for future high-performance smart cardsIEEE Micro, 2003