Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces
Open Access
- 27 May 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (5) , e98395
Abstract
Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations; i) subtraction of the best linear fit from the data (detrending); and ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences −2). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s−2), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s−2). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments.Keywords
This publication has 35 references indexed in Scilit:
- Use of weighted Fourier linear combiner filters to estimate lower trunk 3D orientation from gyroscope sensors dataJournal of NeuroEngineering and Rehabilitation, 2013
- Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging SurfacesJournal of Aging Research, 2012
- Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic ReviewSensors, 2010
- Construct validity of RT3 accelerometer: A comparison of level-ground and treadmill walking at self-selected speedsJournal of Rehabilitation Research and Development, 2010
- Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuationMedical & Biological Engineering & Computing, 2009
- Wearable systems for monitoring mobility-related activities in older people: a systematic reviewClinical Rehabilitation, 2008
- Lumbar and cervical erector spinae fatigue elicit compensatory postural responses to assist in maintaining head stability during walkingJournal of Applied Physiology, 2006
- Reliability of segmental accelerations measured using a new wireless gait analysis systemJournal of Biomechanics, 2006
- Upper body accelerations during walking in healthy young and elderly menGait & Posture, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986