Effect of spatial filtering on crosstalk reduction in surface EMG recordings
Authors:
- Luca MesinLuca Mesin
- Stuart SmithSSStuart Smith
- Suzanne HugoSHSuzanne Hugo
- Suretha ViljoenSVSuretha Viljoen
- Tania HanekomTHTania Hanekom
- 27 June 2008
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 31 (3) , 374-383
Abstract
Increasing the selectivity of the detection system in surface electromyography (EMG) is beneficial in the collection of information of a specific portion of the investigated muscle and to reduce the contribution of undesired components, such as non-propagating components (due to generation or end-of-fibre effects) or crosstalk from nearby muscles. A comparison of the ability of different spatial filters to reduce the amount of crosstalk in surface EMG measurements was conducted in this paper using simulated signals. It focused on the influence of different properties of the muscle anatomy (changing subcutaneous layer thickness, skin conductivity, fibre length) and detection system (single, double and normal double differential, with two inter-electrode distances - IED) on the amount of crosstalk present in the measurements. A cylindrical multilayer (skin, subcutaneous tissue, muscle, bone) analytical model was used to simulate single fibre action potentials (SFAPs). Fibres were grouped together in motor units (MUs) and motor unit action potentials (MUAPs) were obtained by adding the SFAPs of the corresponding fibres. Interference surface EMG signals were obtained, modelling the recruitment of MUs and rate coding. The average rectified value (ARV) and mean frequency (MNF) content of the EMG signals were studied and used as a basis for determining the selectivity of each spatial filter. From these results it was found that the selectivity of each spatial filter varies depending on the transversal location of the measurement electrodes and on the anatomy. An increase in skin conductivity favourably affects the selectivity of normal double differential filters as does an increase in subcutaneous layer thickness. An increase in IED decreases the selectivity of all the analysed filters.Keywords
This publication has 34 references indexed in Scilit:
- Surface EMG Crosstalk Evaluated from Experimental Recordings and Simulated SignalsMethods of Information in Medicine, 2004
- Simulation analysis of the ability of different types of multi-electrodes to increase selectivity of detection and to reduce cross-talkJournal of Electromyography and Kinesiology, 2003
- A simulation study to examine the use of cross-correlation as an estimate of surface EMG cross talkJournal of Applied Physiology, 2003
- Crosstalk in surface electromyography of the proximal forearm during gripping tasksJournal of Electromyography and Kinesiology, 2003
- Neither high-pass filtering nor mathematical differentiation of the EMG signals can considerably reduce cross-talkJournal of Electromyography and Kinesiology, 2002
- Influence of anatomical, physical, and detection-system parameters on surface EMGBiological Cybernetics, 2002
- A convenient method to reduce crosstalk in surface EMGClinical Neurophysiology, 2001
- Compensation of the effect of sub-cutaneous tissue layers on surface EMG: a simulation studyMedical Engineering & Physics, 1999
- Cross talk in surface electromyograms of human hamstring musclesJournal of Orthopaedic Research, 1992
- Surface myoelectric signal cross-talk among muscles of the legElectroencephalography and Clinical Neurophysiology, 1988