The Discontinuous Galerkin Finite Element Method for Solving the MEG and the Combined MEG/EEG Forward Problem
Open Access
- 2 February 2018
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 12, 30
Abstract
In Electro- (EEG) and Magnetoencephalography (MEG), one important requirement of source reconstruction is the forward model. The continuous Galerkin finite element method (CG-FEM) has become one of the dominant approaches for solving the forward problem over the last decades. Recently, a discontinuous Galerkin FEM (DG-FEM) EEG forward approach has been proposed as an alternative to CG-FEM (Engwer et al., 2017). It was shown that DG-FEM preserves the property of conservation of charge and that it can, in certain situations such as the so-called skull leakages, be superior to the standard CG-FEM approach. In this paper, we developed, implemented, and evaluated two DG-FEM approaches for the MEG forward problem, namely a conservative and a non-conservative one. The subtraction approach was used as source model. The validation and evaluation work was done in statistical investigations in multi-layer homogeneous sphere models, where an analytic solution exists, and in a six-compartment realistically shaped head volume conductor model. In agreement with the theory, the conservative DG-FEM approach was found to be superior to the non-conservative DG-FEM implementation. This approach also showed convergence with increasing resolution of the hexahedral meshes. While in the EEG case, in presence of skull leakages, DG-FEM outperformed CG-FEM, in MEG, DG-FEM achieved similar numerical errors as the CG-FEM approach, i.e., skull leakages do not play a role for the MEG modality. In particular, for the finest mesh resolution of 1 mm sources with a distance of 1.59 mm from the brain-CSF surface, DG-FEM yielded mean topographical errors (relative difference measure, RDM%) of 1.5% and mean magnitude errors (MAG%) of 0.1% for the magnetic field. However, if the goal is a combined source analysis of EEG and MEG data, then it is highly desirable to employ the same forward model for both EEG and MEG data. Based on these results, we conclude that the newly presented conservative DG-FEM can at least complement and in some scenarios even outperform the established CG-FEM approaches in EEG or combined MEG/EEG source analysis scenarios, which motivates a further evaluation of DG-FEM for applications in bioelectromagnetism.Keywords
Funding Information
- H2020 Marie Skłodowska-Curie Actions (641652)
- Deutsche Forschungsgemeinschaft (WO1425/7-1, WO1425/5-2, DFG EXC 1003)
This publication has 45 references indexed in Scilit:
- Validation of finite element model of transcranial electrical stimulation using scalp potentials: implications for clinical doseJournal of Neural Engineering, 2013
- Forward Field Computation with OpenMEEGComputational Intelligence and Neuroscience, 2011
- Neuroelectromagnetic Forward Head Modeling ToolboxJournal of Neuroscience Methods, 2010
- A full subtraction approach for finite element method based source analysis using constrained Delaunay tetrahedralisationNeuroImage, 2009
- A generic grid interface for parallel and adaptive scientific computing. Part II: implementation and tests in DUNEComputing, 2008
- A generic grid interface for parallel and adaptive scientific computing. Part I: abstract frameworkComputing, 2008
- Attention Improves Population-Level Frequency Tuning in Human Auditory CortexJournal of Neuroscience, 2007
- Contributions of principal neocortical neurons to magnetoencephalography and electroencephalography signalsThe Journal of Physiology, 2006
- Radial Anisotropy Added to a Spherically Symmetric Conductor Does Not Affect the External Magnetic Field Due to Internal SourcesEurophysics Letters, 1995
- Mixed finite elements in ?3Numerische Mathematik, 1980