Performance of Wavefront‐Guided Soft Lenses in Three Keratoconus Subjects
- 1 December 2008
- journal article
- case report
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (12) , E1172-8
Abstract
Purpose.: To examine whether custom wavefront‐guided soft contact lenses provide visual and optical performance equivalent to habitual gas permeable (GP) corrections in three keratoconus subjects. Methods.: Custom wavefront‐guided soft contact lenses were produced and evaluated at the Visual Optics Institute, College of Optometry, University of Houston for three habitual GP‐wearing keratoconus subjects. Photopic high and mesopic low contrast logarithm of minimum angle of resolution visual acuity (logMAR VA) and residual second to tenth order optical aberrations experienced with these custom soft lenses were recorded and compared with the subjects’ habitual GP correction. Results.: All three subjects wearing custom soft lenses reached the established exit criterion of photopic high contrast (HC) logMAR VA equal to or better than values recorded with their habitual GP lens. HC logMAR VA for GP and custom soft lens correction was 0.01 ± 0.05 and 0.00 ± 0.02 for KC1, 0.20 ± 0.02 and 0.14 ± 0.02 for KC2, and 0.04 ± 0.09 and −0.05 ± 0.05 for KC3, respectively. In addition, KC2 reached the exit criterion of high‐order aberration levels equal to or less than values with their habitual GP lens (GP lens: 0.394 ± 0.024 μm, custom lens: 0.381 ± 0.074 μm). Conclusions.: Custom wavefront‐guided soft contact lenses have been demonstrated to provide equivalent photopic HC logMAR VA to that achieved with habitual GP correction in three keratoconus subjects. Future emphasis will be placed on surpassing habitual GP performance and reaching a normal age‐matched criterion for both VA and aberration measures. Achieving these goals may require a more thorough understanding of the relationship between visual performance and residual aberration experienced during custom lens wear through the use of image quality metrics predictive of visual performance.Keywords
This publication has 26 references indexed in Scilit:
- Effect of Higher-Order Aberrations on Visual Function in Keratoconic Eyes with a Rigid Gas Permeable Contact LensAmerican Journal of Ophthalmology, 2007
- On-eye Performance of Custom Wavefront-guided Soft Contact Lenses in a Habitual Soft Lens-wearing Keratoconic PatientJournal of Refractive Surgery, 2007
- Correcting anterior corneal aberration and variability of lens movements in keratoconic eyes with back-surface customized soft contact lensesOptics Letters, 2007
- Magnitude and Orientation of Zernike Terms in Patients with KeratoconusInvestigative Ophthalmology & Visual Science, 2007
- Uncorrected Wavefront Error and Visual Performance During RGP Wear in KeratoconusOptometry and Vision Science, 2007
- Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyesOptics Letters, 2007
- Metrics of Retinal Image Quality Predict Visual Performance in Eyes With 20/17 or Better Visual AcuityOptometry and Vision Science, 2006
- Making sense out of wavefront sensingAmerican Journal of Ophthalmology, 2005
- Simulated Optical Performance of Custom Wavefront Soft Contact Lenses for KeratoconusOptometry and Vision Science, 2003
- Visual Acuity Changes Throughout Adulthood in Normal, Healthy Eyes: Seeing Beyond 6/6Optometry and Vision Science, 1995