Multiwavelength Photoacoustic Breath Analysis Sensor for the Diagnosis of Lung Diseases: COPD and Asthma
Open Access
- 23 October 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (11) , 4111-4120
Abstract
Breath analysis is emerging as a universal diagnostic method for clinical applications. The possibility of breath analysis is being explored vigorously using different analytical techniques. We have designed and assembled a multiwavelength UV photoacoustic spectroscopy (PAS) sensor for the said application. To optimize laser wavelength for sample excitation, photoacoustic signals from disease and normal conditions are recorded with different laser excitations (213, 266, 355, and 532 nm) on exhaled breath samples. Principal component analysis (PCA) of the PA signals has shown that 213, 266, and 355 nm laser excitations are suitable for breath analysis, with reliable descriptive statistics obtained for 266 nm laser. The study has, therefore, been extended for breath samples collected from asthma, chronic obstructive pulmonary disease (COPD), and normal subjects, using 266 nm laser excitation. PCA of the PA data shows good classification among asthma, COPD, and normal subjects. Match/No-match study performed with asthma, COPD, and normal calibration set has demonstrated the potential of using this method for diagnostic application. Sensitivity and specificity are observed as 88 and 89%, respectively. The area under the curve of the ROC curve is found to be 0.948, which justifies the diagnostic capability of the device for lung diseases. The same samples were studied using a commercial E-Nose, and the measurement outcome strongly supports the PAS results.Keywords
Funding Information
- Manipal Academy of Higher Education
This publication has 31 references indexed in Scilit:
- A systematic review of breath analysis and detection of volatile organic compounds in COPDJournal of Breath Research, 2016
- Real-time monitoring of hydrogen cyanide (HCN) and ammonia (NH 3 ) emitted by Pseudomonas aeruginosaJournal of Breath Research, 2015
- Real-time monitoring of endogenous lipid peroxidation by exhaled ethylene in patients undergoing cardiac surgeryAmerican Journal of Physiology-Lung Cellular and Molecular Physiology, 2014
- An electronic nose in the discrimination of patients with non-small cell lung cancer and COPDLung Cancer, 2009
- Receiver-Operating Characteristic Analysis for Evaluating Diagnostic Tests and Predictive ModelsCirculation, 2007
- Current status of clinical breath analysisApplied Physics B, 2006
- Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysisProceedings of the National Academy of Sciences of the United States of America, 2001
- The Use of Gas-Phase UV Spectra in the 168−330-nm Wavelength Region for Analytical Purposes. 1. Qualitative MeasurementsAnalytical Chemistry, 1998
- The use of the area under the ROC curve in the evaluation of machine learning algorithmsPattern Recognition, 1997
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978