Voxel‐wise uncertainty in CT substitute derived from MRI
Authors:
- Adam JohanssonAJAdam Johansson
- Mikael KarlssonMKMikael Karlsson
- Jun YuJYJun Yu
- Thomas AsklundTAThomas Asklund
- Tufve NyholmTNTufve Nyholm
- 22 May 2012
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 39 (6Part1) , 3283-3290
Abstract
Purpose:: In an earlier work, we demonstrated that substitutes for CT images can be derived from MR images using ultrashort echo time (UTE) sequences, conventional T2 weighted sequences, and Gaussian mixture regression (GMR). In this study, we extend this work by analyzing the uncertainties associated with the GMR model and the information contributions from the individual imaging sequences.Methods:: An analytical expression for the voxel‐wise conditional expected absolute deviation (EAD) in substitute CT (s‐CT) images was derived. The expression depends only on MR images and can thus be calculated along with each s‐CT image. The uncertainty measure was evaluated by comparing the EAD to the true mean absolute prediction deviation (MAPD) between the s‐CT and CT images for 14 patients. Further, the influence of the different MR images included in the GMR model on the generated s‐CTs was investigated by removing one or more images and evaluating the MAPD for a spectrum of predicted radiological densities.Results:: The largest EAD was predicted at air‐soft tissue and bone‐soft tissue interfaces. The EAD agreed with the MAPD in both these regions and in regions with lower EADs, such as the brain. Two of the MR images included in the GMR model were found to be mutually redundant for the purpose of s‐CT generation.Conclusions:: The presented uncertainty estimation method accurately predicts the voxel‐wise MAPD in s‐CT images. Also, the non‐UTE sequence previously used in the model was found to be redundant.Keywords
This publication has 20 references indexed in Scilit:
- The effect of errors in segmented attenuation maps on PET quantificationMedical Physics, 2011
- Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regionsRadiation Oncology, 2010
- Dedicated Magnetic Resonance Imaging in the Radiotherapy ClinicInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumoursRadiotherapy and Oncology, 2008
- A simulation of MRI based dose calculations on the basis of radiotherapy planning CT imagesActa Oncologica, 2008
- Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?Radiology, 2007
- Feasibility of using MRI alone for 3D Radiation Treatment Planning in Brain TumorsJapanese Journal of Clinical Oncology, 2007
- Clinical ultrashort echo time imaging of bone and other connective tissuesNMR in Biomedicine, 2006
- Dosimetric evaluation of MRI-based treatment planning for prostate cancerPhysics in Medicine & Biology, 2004
- Magnetic Resonance: An Introduction to Ultrashort TE (UTE) ImagingJournal of Computer Assisted Tomography, 2003