Seismic performance assessment of underground utility tunnel and internal pipeline considering effects of tunnel joints
Authors:
Open Access
- 1 January 2024
- journal article
- research article
- Published by The Japanese Geotechnical Society in Japanese Geotechnical Society Special Publication
- Vol. 10 (20) , 710-714
Abstract
Underground utility tunnel is a passage built underground to carry utility pipelines such as electricity, steam, water, and sewer pipelines. To ensure the quality and efficiency of the construction, circumferential joints are always installed between two adjacent tunnel segments to prevent damage caused by shrinkage and creep of mass concrete in construction, and uneven settlement during daily operation. However, the lack of verification and quantification of the seismic performance of utility tunnel and internal pipeline system considering the effects of joints remains a critical deficiency of the design of utility tunnels in seismic intensive regions. This study aims to investigate the response of long-extended underground utility tunnel and internal pipeline system subjected to non-uniform earthquake ground motions. The utility tunnel and internal pipeline system are modeled as a double-beam system on foundation using OpenSees software. Soil-structure interaction, joint connections and internal pipeline pedestals are modeled as springs with different mechanical properties. A typical response-spectrum compatible bedrock ground motion (including two directions) is collectively amplified into different intensity levels. One-dimensional dynamic site response analysis and wave passage effect are conducted before dynamic analyses of the utility tunnel and internal pipeline system. The numerical results indicate that the utility tunnel joints can help to mitigate the seismic damage of utility tunnel, while enlarge the seismic response of internal pipeline. For the case of 0.20 g intensity level, the axial force, shear force, and bending moment of the utility tunnel with joints are 41.15%, 54.92%, and 78.09% less than those without joints, respectively; the internal pipeline in utility tunnel with joints exhibits significant increases of 21.67%, 1667.24%, and 40.02% in axial force, shear force, and bending moment compared to those without joints. The increasing rates of utility tunnel and internal pipeline responses diminish as seismic intensity levels rise, indicating a progressive plastic deformation within the structures.Keywords
This publication has 7 references indexed in Scilit:
- Seismic fragility analysis of water supply pipelines retrofitted with corrosion-protection liner buried in non-uniform siteSoil Dynamics and Earthquake Engineering, 2023
- Seismic behaviors of utility tunnel-soil system: With and without joint connectionsUnderground Space, 2022
- Experimental study on the mechanical behavior of utility tunnel with flexible joints passing through active thrust faultArabian Journal of Geosciences, 2021
- Seismic Performance Evaluation of Two-story and Three-span Subway Station in Different Engineering SitesJournal of Earthquake Engineering, 2021
- Shaking table tests of the seismic response of a utility tunnel with a joint connectionSoil Dynamics and Earthquake Engineering, 2020
- Experimental Study on Seismic Performance of Prefabricated Joints of Underground Utility TunnelIOP Conference Series: Earth and Environmental Science, 2019
- Numerical simulation and seismic performance evaluation of buried pipelines rehabilitated with cured‐in‐place‐pipe liner under seismic wave propagationEarthquake Engineering & Structural Dynamics, 2016