Abstract
The adaptive-series-virtual-impedance (ASVI) control strategy is an attractive load stabilization method for cascaded systems thanks to its adaptive capacity for different source converters and better load performance. However, as reported in the previous literature, this ASVI control strategy has a potential problem: Since it utilizes a proportional-integral (PI) controller to find the center frequency of the ASVI, the PI controller may miss it with excessive proportional or integral coefficients and lead to the failure of the ASVI control strategy. Although this potential problem may not arise with small proportional and integral coefficients, it is a hidden trouble for the ASVI control strategy. To make the ASVI control strategy more reliable, a minimum-ripple-point-tracking (MRPT) controller is proposed to replace the original PI controller in this letter. With the MRPT controller, the center frequency of ASVI is found via the perturb and observe algorithm, which ensure the ASVI control strategy do not have the aforementioned potential problem anymore. Furthermore, in order to find the center frequency of ASVI quickly, the sinusoidal-tracking algorithm is further introduced into the MRPT controller to improve its processing speed. Finally, a load converter cascaded with different $LC$ input filters are fabricated to validate the proposed MRPT controller.
Funding Information
  • Engineering and Physical Sciences Research Council (EP/I038586/1)

This publication has 8 references indexed in Scilit: