Purpose: To assess efficacy and safety of cone beam computed tomography (CBCT) in the radiofrequency ablation (RFA) of osteoid osteoma (OO) in children and adolescents, and to compare technical success, clinical success, radiation dose and procedure duration time of CBCT guidance to conventional computed tomography (CT) guidance. Materials and methods: Between 2015 and 2019, 53 consecutive percutaneous RFA were performed on pediatric patients with CBCT or conventional CT guidance, respectively, in 24 and 29 children and adolescents with 24-month follow-up. Dose area product (DAP) and dose length product (DLP) were recorded, respectively, for CBCT and conventional CT and converted to effective doses (ED). Results: CBCT and conventional CT groups were similar in terms of patient age and weight, tumor size and tumor location. Technical success was achieved in all cases. Primary clinical success was 91.67% (22/24) for the CBCT group and 89.66% (26/29) for the conventional CT group. Mean DAP was 64.75Gycm2 (range 6.0–266.7). Mean DLP was 972.62mGycm (range 337–2344). ED was significantly lower in the CBCT group compared to the conventional CT group (0.34 mSv vs. 5.53 mSv, p = 0.0119). Procedure duration time was not significantly longer in the CBCT group (102.25 min vs. 92.34 min, p = 0.065). No major complication was registered. Minor complications were observed in 4 patients (2 in CBCT; 2 in conventional CT). Conclusions: Compared to conventional CT guidance, CBCT guidance for percutaneous OO ablation shows similar technical and clinical success rates, with reduced radiation dose and equivalent procedure duration time. This technique helps sparing dose exposure to pediatric patients.Keywords
This publication has 38 references indexed in Scilit:
- Communication of Findings of Radiologic Examinations: Medicolegal ConsiderationsSeminars in Ultrasound, CT and MRI, 2012
- Pediatric Bone Imaging: Diagnostic Imaging of Osteoid OsteomaAmerican Journal of Roentgenology, 2012
- Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot StudyCardioVascular and Interventional Radiology, 2010
- C-arm Cone-beam CT: General Principles and Technical Considerations for Use in Interventional RadiologyJournal of Vascular and Interventional Radiology, 2008
- Efficacy of percutaneous radiofrequency ablation of osteoid osteoma in childrenPediatric Radiology, 2007
- Issues in Imaging-Guided Tumor Ablation in Children Versus AdultsAmerican Journal of Roentgenology, 2007
- Symptomatic resolution of spinal osteoid osteoma with conservative management: imaging correlationSkeletal Radiology, 2007
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007
- Technical Considerations in CT-Guided Radiofrequency Thermal Ablation of Osteoid Osteoma: Tricks of the TradeAmerican Journal of Roentgenology, 2002
- Assessment of organ radiation doses and associated risk for digital bifemoral arteriographyBritish Journal of Radiology, 1995