Multiplex immunoassay based on biochip technology for the screening of antibiotic residues in milk: validation according to the European guideline
- 2 December 2018
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 35 (12) , 2348-2365
Abstract
The Infiniplex for milk® (IPM) kit is a quick method for the simultaneous and qualitative detection of more than 100 molecules including antibiotic residues, mycotoxins, anti-inflammatories and antiparasitic drugs into a single test that does not require milk treatment. The IPM® kit was validated according to the European decision EC/2002/657 and according to the European guideline for the validation of screening methods (2010). Our validation was focused only on antibiotic residues. The washing step was identified as the most critical step of the assay. Insufficient washes could cause a significant background noise that prevents imaging. Positive controls have to be freshly prepared each day (insufficient stability). The method was specific with a low false-positive rate of 1.7% on 5 discrete test regions (DTR) ((beta-lactams, lincomycin, virginiamycin, quinolones and sulphonamides)) and a false-positive rate of 0% on the 26 other DTR. During our validation, the 42 determined detection capabilities CCβ for 12 antibiotic families (aminoglycosides, cephalosporins, lincosamides, macrolides, miscellaneous antibiotics, penicillins, phenolated polymixins, polypeptide antibiotics, quinolones, sulphonamides, tetracyclines) were at between once and twice the decision levels stated by the manufacturer. Forty CCβ determined were lower than the respective regulatory limits (i.e. MRL, RC, MRPL) in milk, except for tilmicosin (1.5 times the MRL) and neospiramycin (>1.25 times the MRL). The estimated CCβ of thiamphenicol, cloxacillin, danofloxacin, sulphathiazol, ceftiofur and sulphamonomethoxine were lower than or at the MRL. However, it was difficult to approach an accurate CCβ with only qualitative results. It is impossible to know whether or not we were close to the cut-off value. The software could be improved by differentiating between low-positive and high-positive results. The results of our participation in three qualitative proficiency tests in 2016 and 2017 for the detection of quinolones, tetracyclines and sulphonamides in cows’ milk were very satisfactory.Keywords
This publication has 27 references indexed in Scilit:
- Rapid screening of multiple antibiotic residues in milk using disposable amperometric magnetosensorsAnalytica Chimica Acta, 2014
- Integrated disposable electrochemical immunosensors for the simultaneous determination of sulfonamide and tetracycline antibiotics residues in milkBiosensors and Bioelectronics, 2013
- Comparison of Different Elisa Formats for the Detection of Cephalexin and Application ValidationAnalytical Letters, 2012
- Validation of the Delvotest SP NT DAJournal of AOAC INTERNATIONAL, 2012
- Validation of a liquid chromatography-tandem mass spectrometry screening method to monitor 58 antibiotics in milk: a qualitative approachFood Additives & Contaminants: Part A, 2009
- Label-Free and Multiplex Detection of Antibiotic Residues in Milk Using Imaging Surface Plasmon Resonance-Based ImmunosensorAnalytical Chemistry, 2009
- Comprehensive fast multiresidue screening of 150 veterinary drugs in milk by ultra-performance liquid chromatography coupled to time of flight mass spectrometryJournal of Chromatography B, 2009
- Lab-on-a-chip for Analysis and Diagnostics: Application to Multiplexed Detection of Antibiotics in Milk2009
- Generation of Broad Specificity Antibodies for Sulfonamide Antibiotics and Development of an Enzyme-Linked Immunosorbent Assay (ELISA) for the Analysis of Milk SamplesJournal of Agricultural and Food Chemistry, 2009
- Validation of a microbiological method: the STAR protocol, a five-plate test, for the screening of antibiotic residues in milkFood Additives & Contaminants, 2004