Effect of moisture and thermal degradation on the activation energy of oil–paper insulation in frequency domain spectroscopy measurement
Authors:
Open Access
- 1 June 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (9) , 2042-2049
Abstract
Frequency domain spectroscopy (FDS) is widely used to diagnose the condition of transformer oil–paper insulation. However, FDS measurements are highly temperature dependent. The master curve technique is the most common method to remove the temperature effect on FDS, but the reliability of this method is largely dependent on the value of the activation energy, which can be affected by moisture content and thermal degradation degree. To understand the effects of these two factors on the activation energy, FDS measurements at different temperatures were performed on oil‐impregnated pressboards with different thermal degradation degrees and moisture contents. The activation energies of the pressboards were calculated using the Arrhenius equation. Results show that they vary between 0.88 and 1.06 eV along with thermal degradation degree and moisture. The two‐way ANOVA indicates that the effects of these two factors on activation energy are not significant at 95% confidence level when the degree of polymerisation (DP) changes from 415 to 1300 and when the moisture does not exceed 4%. The average activation energy (0.95 eV) can be utilised to generalise the Arrhenius equation to better eliminate the temperature effects. Finally, FDS measurements on a model transformer are performed to verify the effectiveness of the proposed technique.Keywords
Funding Information
- National Natural Science Foundation of China (51277187)
This publication has 28 references indexed in Scilit:
- Life evaluation of insulation paper used in transformer by determining the activation energyMaterials Research Innovations, 2015
- Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation systemIET Electric Power Applications, 2015
- Influence of temperature and moisture content on frequency response analysis of transformer windingIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Understanding the impact of moisture and ageing of transformer insulation on frequency domain spectroscopyIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Influence of Temperature and Moisture Level in Paper-Oil Insulation on the Parameters of the Cole-Cole ModelIEEE Transactions on Power Delivery, 2013
- On the Feasibility of Using Poles Computed from Frequency Domain Spectroscopy to Assess Oil Impregnated Paper Insulation ConditionsEnergies, 2013
- Quantitative analysis of ageing condition of oil-paper insulation by frequency domain spectroscopyIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Fault diagnosis of power transformers using multi-class least square support vector machines classifiers with particle swarm optimisationIET Electric Power Applications, 2011
- Dielectric response of mineral oil impregnated cellulose and the impact of agingIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Frequency Response of Oil Impregnated Pressboard and Paper Samples for Estimating Moisture in Transformer InsulationIEEE Transactions on Power Delivery, 2006