The Architectural Design of Building Façade Models Related to Optimizing Daylight Distribution
Open Access
- 7 May 2023
- journal article
- research article
- Published by SolarLits in Journal of Daylighting
- Vol. 10 (1) , 60-71
Abstract
Lighting control integrated with daylighting is recognized as an important and useful strategy in energy efficient building design. One of the right factors to reduce energy consumption for artificial lighting during the day is the maximum utilization of sunlight. The aim of this research, distribution of daylight into the building analysis with five models of building facades and value of illuminance in the morning, afternoon and evening with orientation of the window openings to the northeast and southwest. Bank Mega is one of the tall buildings in Makassar Indonesia, which is located in a coastal area that is not blocked by other tall buildings, so this building is the object of research as a basis for designing façade models on building envelopes. The methodology this study is quantitative, analyzing the performance of sunlight as a source of daylighting in office buildings. This paper presents field measurements in office buildings, namely in rooms that are oriented northeast and southwest. The analysis in the two spaces is a reference to determine the effect of sunlight on the orientation of the building. In this study also conducted visual perception experiments by submitting questionnaires to 43 respondents. the results show that there are some complaints for employees, because of the high illuminance value in certain areas. Furthermore, simulate using the Radiance Illuminance Program software to determine the illuminance value of room in the morning, noon and afternoon with five building facade model designs, i.e., massive glass, vertical, horizontal, diagonal, and vertical-diagonal model. The results presented in this paper show that the distribution of daylight in an east-oriented room is higher in the morning than in the evening and noon. Whereas in the southwest orientation it is inversely proportional, the value of light distribution is higher in the afternoon than in the morning and noon. Accordingly, orientation of the building affects distribution of daylight. The massive glass facade model without using sun shading has the highest light distribution value compared to other façade models, but can cause glare and excessive brightness. Furthermore, the second highest distribution of daylight with the vertical facade model, but there are also areas that exceed the standard illuminance level for workspaces, but only in areas near window openings. The combined model of the vertical-diagonal facade which also has a high distribution of illuminance value and to redirect daylight deep into building interior simultaneously in the morning, afternoon and evening. Accordingly, façade model on envelope of building affects distribution of daylight. The aesthetic value of architectural design shows that the appearance of the building does not look monotonous or massive, when using the building facade models because there are attractive areas in the building envelope. Header of solarlits.comKeywords
This publication has 29 references indexed in Scilit:
- The effects of shading devices on office building energy performance in Mediterranean climate regionsJournal of Building Engineering, 2021
- Building facade multi-objective optimization for daylight and aesthetical perceptionBuilding and Environment, 2019
- Blinded by the light: Occupant perceptions and visual comfort assessments of three dynamic daylight control systems and shading strategiesBuilding and Environment, 2019
- Stimulus range bias leads to different settings when using luminance adjustment to evaluate discomfort due to glareBuilding and Environment, 2019
- Temporal effects on glare response from daylightBuilding and Environment, 2017
- Investigation of existing discomfort glare indices using human subject study dataBuilding and Environment, 2017
- Optimization of facade design based on the impact of interior obstructions to daylightingBuilding Simulation, 2015
- Efficient visible light driven photocatalytic removal of NO with aerosol flow synthesized B, N-codoped TiO2 hollow spheresJournal of Hazardous Materials, 2011
- The effects of window proximity, partition height, and gender on perceptions of open-plan officesJournal of Environmental Psychology, 2007
- Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD camerasEnergy and Buildings, 2006