Semi-Active Fluid Viscous Dampers for Seismic Mitigation of RC Elevated Liquid Storage Tanks
- 10 March 2019
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
- Vol. 19 (03)
Abstract
The effectiveness of the semi-active control strategies using fluid viscous dampers (SAFVDs) for seismic mitigation of reinforced concrete (RC) elevated liquid storage tanks is investigated. Three control algorithms are employed for regulating the damping coefficient of the SAFVDs: (1) Passive-OFF, (2) Passive-ON, and (3) Clipped Optimal Control (COC). The uncontrolled response of the tank is compared with those installed with SAFVD of different control algorithms. Focus is also placed on various positions of the dampers, viz., dampers installed at alternate levels (Configurations I, II, IV, and V) and at all levels (Configurations III and VI) of the staging. A discrete two-mass model for the liquid and multi-degree-of-freedom system for the staging, installed with the dampers, is developed for the RC elevated liquid storage tanks. The response of the broad and slender tanks is studied, for which the ratios of the height of the liquid to the radius of the container are 0.5 and 2.0, respectively. The time-history response of the elevated tank is evaluated for eight different earthquake ground motions, including near- and far-field earthquakes. A MATLAB code was developed to solve the coupled differential equations of motion of the system using the state-space approach. Key parameters, viz., convective displacement, rigid mass displacement, base shear, overturning moment, and damper force, are evaluated. The results show that all the control systems considered herein are beneficial in reducing the seismic responses. The frequency response function for the uncontrolled and semi-actively controlled liquid storage tank in frequency domain exhibits significant response reduction, highlighting the effectiveness of the SAFVDs. The structural response is effectively controlled using the SAFVDs with Passive-OFF (valve closed) and COC algorithms. The COC algorithm employed in this study is a promising candidate for the seismic mitigation of RC elevated liquid storage tanks using the semi-active control.Keywords
This publication has 32 references indexed in Scilit:
- Optimal control of dynamical systems and structures under stochastic uncertaintyAdvances in Engineering Software, 2012
- Stochastic optimal structural control: Stochastic optimal open-loop feedback controlAdvances in Engineering Software, 2011
- Seismic response of liquid-filled elevated tanksEngineering Structures, 2011
- Variable dampers for earthquake protection of benchmark highway bridgesSmart Materials and Structures, 2009
- Earthquake response of isolated elevated liquid storage steel tanksJournal of Constructional Steel Research, 2003
- Supplemental energy dissipation: state-of-the-art and state-of-the-practiceEngineering Structures, 2002
- Semi-active control systems for seismic protection of structures: a state-of-the-art reviewEngineering Structures, 1999
- Semiactive Control Algorithms for Structures with Variable DampersJournal of Engineering Mechanics, 1998
- Modeling and control of magnetorheological dampers for seismic response reductionSmart Materials and Structures, 1996
- Vibration studies and tests of liquid storage tanksEarthquake Engineering & Structural Dynamics, 1983