Gas equilibrium membrane inlet mass spectrometry (GE-MIMS) for water at high pressure
Open Access
- 12 January 2024
- journal article
- research article
- Published by Copernicus GmbH in Geoscientific Instrumentation, Methods and Data Systems
- Vol. 13 (1) , 1-8
Abstract
Gas species are widely used as natural or artificial tracers to study fluid dynamics in environmental and geological systems. The recently developed gas equilibrium membrane inlet mass spectrometry (GE-MIMS) method is most useful for accurate and autonomous on-site quantification of dissolved gases in aquatic systems. GE-MIMS works by pumping water through a gas equilibrator module containing a gas headspace, which is separated from the water by a gas-permeable membrane. The partial pressures of the gas species in the headspace equilibrate with the gas concentrations in the water according to Henry's Law and are quantified with a mass spectrometer optimized for low gas consumption (miniRUEDI or similar). However, the fragile membrane structures of the commonly used equilibrator modules break down at water pressures ≳3 bar. These modules are therefore not suitable for use in deep geological systems or other environments with high water pressures. To this end, the SysMoG® MD membrane module (Solexperts AG, Switzerland; “SOMM”) was developed to withstand water pressures of up to 100 bar. Compared to the conventionally used GE-MIMS equilibrator modules, the mechanically robust construction of the SOMM module entails slow and potentially incomplete gas–water equilibration. We tested the gas equilibration efficiency of the SOMM and developed an adapted protocol that allows correct operation of the SOMM for GE-MIMS analysis at high water pressures. This adapted SOMM GE-MIMS technique exhibits a very low gas consumption from the SOMM to maintain the gas–water equilibrium according to Henry's Law and provides the same analytical accuracy and precision as the conventional GE-MIMS technique. The analytical potential of the adapted SOMM GE-MIMS technique was demonstrated in a high-pressure fluid migration experiment in an underground rock laboratory. The new technique overcomes the pressure limitations of conventional gas equilibrators and thereby opens new opportunities for efficient and autonomous on-site quantification of dissolved gases in high-pressure environments, such as in research and monitoring of underground storage of CO2 and waste deposits or in the exploration of natural resources.Keywords
All Related Versions
This publication has 37 references indexed in Scilit:
- Natural CO2Seeps Offshore Panarea: A Test Site for Subsea CO2Leak Detection TechnologyMarine Technology Society Journal, 2015
- Excess air formation as a mechanism for delivering oxygen to groundwaterWater Resources Research, 2013
- A membrane inlet mass spectrometry system for noble gases at natural abundances in gas and water samplesRapid Communications in Mass Spectrometry, 2013
- Argon Concentration Time-Series As a Tool to Study Gas Dynamics in the Hyporheic ZoneEnvironmental Science & Technology, 2013
- Noble Gas Thermometry in Groundwater Hydrology2013
- Membrane Inlet Mass Spectrometer for the Quasi-Continuous On-Site Analysis of Dissolved Gases in GroundwaterEnvironmental Science & Technology, 2012
- Underwater cryotrap‐membrane inlet system (CT‐MIS) for improved in situ analysis of gasesLimnology and Oceanography: Methods, 2012
- Continuous High-Frequency Dissolved O2/Ar Measurements by Equilibrator Inlet Mass SpectrometryAnalytical Chemistry, 2009
- Application of membrane inlet mass spectrometry for online and in situ analysis of methane in aquatic environmentsJournal of the American Society for Mass Spectrometry, 2008
- Noble Gases in Lakes and Ground WatersReviews in Mineralogy and Geochemistry, 2002