Comparison of the response of primary human blood monocytes and the U937 human monocytic cell line to two different sizes of alumina ceramic particles
Authors:
- Peter KazmierPKPeter Kazmier
- Mohamed N. RahamanMRMohamed N. Rahaman
- B. Sonny BalBBB. Sonny Bal
- Ronald K. TessmanRTRonald K. Tessman
- D. Mark EstesDED. Mark Estes
- 1 July 2004
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 22 (4) , 832-838
Abstract
It is well recognized that wear particles derived from orthopaedic implants have the potential to induce inflammation, which may eventually lead to aseptic loosening of the artificial joint. We hypothesized that alumina ceramic particles of different sizes cause a differential cytokine response by human monocytes. To test this hypothesis a human monocytic cell line (U937) and primary human blood monocytes obtained from healthy volunteers were exposed to ceramic particles within the range known to be generated in vivo. Cellular responses were measured by quantifying the relative gene expression of 12 different cytokines using TAQman Real‐Time Polymerase Chain Reaction (RT‐PCR). Our results demonstrate that at a particle to cell ratio of 100:1, 0.5 μm ceramic particles consistently provoked higher amounts of Interleukin‐1α (IL‐1α), IL‐1β, IL‐8, IL‐10 and Tumor necrosis factor‐α (TNF‐α) steady state mRNA by U937 cells. As expected, the variability of cytokine expression in primary blood monocytes was much higher compared to the cell line however, a similar trend was observed. These results show a differential response to ceramic particle size, which may imply that 0.5 μm particles are less biocompatible. New ceramic implants can be designed to generate a known particle size range in vivo. Implant materials of this type may induce relatively lower levels of production of inflammatory cytokines resulting in a reduced incidence of failure due to aseptic loosening. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.Keywords
This publication has 34 references indexed in Scilit:
- Differential apoptotic response of J774 macrophages to alumina and ultra‐high‐molecular‐weight polyethylene particlesJournal of Orthopaedic Research, 2002
- Interleukin-10 inhibits polymethylmethacrylate particle induced interleukin-6 and tumor necrosis factor-α release by human monocyte/macrophages in vitroBiomaterials, 2001
- Correlation of synovial fluid cytokine levels with histological and clinical parameters of primary and revision total hip and total knee replacementsActa Orthopaedica, 2001
- pH Sensing with mesoporous thin filmsChemical Communications, 2000
- Alumina Ceramic Bearings for Hip EndoprosthesesClinical Orthopaedics and Related Research, 2000
- Ceramic Hip Prostheses in Young PatientsClinical Orthopaedics and Related Research, 2000
- Spectroscopy of Fluorescein (FITC) Dyed Colloidal Silica SpheresThe Journal of Physical Chemistry B, 1999
- TNFα-Sekretion durch Abriebpartikel im humanen Makrophagenmodell und deren Modulation durch Medikamente - TNF Response of Macrophages to Wear Particles, and its Modification by DrugsBiomedical Engineering / Biomedizinische Technik, 1999
- Human arthroplasty derived macrophages differentiate into osteoclastic bone resorbing cellsAnnals of the Rheumatic Diseases, 1997
- Establishment and characterization of a human histiocytic lymphoma cell line (U‐937)International Journal of Cancer, 1976