Effect of respiration on the B0 field in the human spinal cord at 3T
Open Access
- 3 January 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (6) , 1629-1636
Abstract
Purpose: Respiration affects the bulk magnetic susceptibility, causing frequency shifts as shown in the brain at 7T. Due to the close proximity of the spine to the lungs, this effect is expected to be even larger in the spinal cord, resulting in detrimental B0 offset. The goal of this study was to quantify the effect of respiration on B0 variation in the spinal cord.Methods: Seven healthy subjects were scanned at 3T. Field maps were acquired during inspired and expired conditions. Frequency shift was quantified in the brain, brainstem, and cervico‐thoracic spinal cord. A skewed Gaussian function with linear term was fitted to the frequency shift as a function of z‐location along the spine.Results: Large frequency shifts were measured along the cord, with a maximum of 74 Hz at C7 (P < 0.05), corresponding to 0.58 ppm. The proposed model was adequately fitted to the respiratory‐induced frequency‐shifts (adjusted R2 = 0.9954). The morphology of subjects (weight and height) seemed to have an impact on the amplitude of frequency shift, although correlations were not significant.Conclusions: This study provides a deeper understanding of the contribution of respiration to B0 shift in the spinal cord. The proposed model can be useful for designing future hardware or software strategies to compensate for these B0 variations dynamically. Magn Reson Med 72:1629–1636, 2014.Keywords
This publication has 32 references indexed in Scilit:
- Combined T2*-weighted measurements of the human brain and cervical spinal cord with a dynamic shim updateNeuroImage, 2013
- Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cordNeuroImage, 2012
- Dynamic multi-coil shimming of the human brain at 7TJournal of Magnetic Resonance, 2011
- Robust fully automated shimming of the human brain for high‐field 1H spectroscopic imagingMagnetic Resonance in Medicine, 2006
- Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coilsMagnetic Resonance in Medicine, 2005
- On the origin of respiratory artifacts in BOLD-EPI of the human brainMagnetic Resonance Imaging, 2002
- Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changesPhysics in Medicine & Biology, 2001
- A model for susceptibility artefacts from respiration in functional echo-planar magnetic resonance imagingPhysics in Medicine & Biology, 2000
- Field-frequency locked in vivo proton MRS on a whole-body spectrometerMagnetic Resonance in Medicine, 1999
- k‐space detection and correction of physiological artifacts in fMRIMagnetic Resonance in Medicine, 1997