(1) Background: The sterile latex surgical glove is an important part of protecting both the patient and the surgical team from infections. However, mechanical stress can damage the integrity of the glove material and thus may lead to infections. (2) Method: A total of 896 gloves from 448 surgeries were tested and evaluated by the water tightening test according to EN455 and ASTM D5151-19. (3) Results: From 448 surgeries, 18.8% of the interventions showed glove damage. In vascular surgery, gloves were damaged in 20.8%, in thoracic surgery 9.1%, in laparoscopic interventions 21.7%, in the subgroup hernia surgeries (TAPP) 17.6% and in open interventions 17.6%. A total of 101 damages were found on 896 gloves; one glove could have several damages. During vascular surgery, 60% of the damages were on the subordinated hand of the surgeon, and 73.3% of the damages had a size of 1 mm. In laparoscopic procedures, the subordinated hand was also more frequently affected (61.3%) than the dominant hand; 64.5% of the damages were 1 mm in size. In the hernia surgery subgroup (TAPP), no damage was larger than 1 mm; 66.7% were in the subordinated hand area. The duration of surgery had no influence on the lesion rate. (4) Conclusion: The damage rate in low impact procedures is high and represents an underestimated problem in soft tissue surgery. The use of single gloving can therefore lead to the risk of infection. EN455 and ASTM D5151-19 does not take into consideration the risk of intraoperative lesions. Double gloving and glove change algorithms should be established.Keywords
This publication has 29 references indexed in Scilit:
- Perforation of Surgical Gloves during Lower Extremity Fracture Surgery and Hip Joint Replacement SurgeryHip & Pelvis, 2015
- Is the surgical knot tying technique associated with a risk for unnoticed glove perforation? An experimental studyPatient Safety in Surgery, 2014
- Risk of Glove Perforation With Arthroscopic Knot Tying Using Different Surgical Gloves and High–Tensile Strength SuturesArthroscopy, 2013
- Continued Non-Compliance with the American College of Surgeons Recommendations To Decrease Infectious Exposure in the Operating Room: Why?Surgical Infections, 2013
- Evaluation of Surgical Glove Perforation after Laparoscopic and Open CholecystectomyActa Chirurgica Belgica, 2013
- Wann sollte in Operationsräumen ein Wechsel chirurgischer Handschuhe erfolgen?Zentralblatt fur Chirurgie, 2010
- Incidence of Microperforation for Surgical Gloves Depends on Duration of WearInfection Control & Hospital Epidemiology, 2009
- Evolution of the Surgical GloveJournal of the American College of Surgeons, 2008
- Glove perforation in orthopaedic and trauma surgeryThe Journal of Bone and Joint Surgery. British volume, 2004
- Frequency of glove perforations and subsequent blood contact in association with selected obstetric surgical proceduresAmerican Journal of Obstetrics and Gynecology, 1993