Antigen Detection Tests for SARS-CoV-2: a systematic review and meta-analysis on real world data.
Authors:
- Matteo RiccòMatteo Riccò
- Silvia RanzieriSRSilvia Ranzieri
- Simona PeruzziSPSimona Peruzzi
- Marina ValenteMVMarina Valente
- Federico MarchesiFMFederico Marchesi
- Nicola Luigi BragazziNicola Luigi Bragazzi
- Davide DonelliDavide Donelli
- Federica BalzariniFBFederica Balzarini
- Pietro FerraroPietro Ferraro
- Vincenza GianfrediVGVincenza Gianfredi
- Carlo SignorelliCSCarlo Signorelli
Open Access
- 11 May 2022
- journal article
- research article
- Vol. 93 (2) , e2022036
Abstract
Background and aim Rapid antigen detection (RAD) tests on nasopharyngeal specimens have been recently made available for SARS-CoV-2 infections, and early studies suggested their potential utilization as rapid screening and diagnostic testing. The present systematic review and meta-analysis was aimed to assess available evidence and to explore the reliability of antigenic tests in the management of the SARS-CoV-2 pandemic. We reported our meta-analysis according to the PRISMA statement. We searched Pubmed, Embase, and pre-print archive medRxiv.og for eligible studies published up to November 5th, 2020. Raw data included true/false positive and negative tests, and the total number of tests. Sensitivity and specificity data were calculated for every study, and then pooled in a random-effects model. Heterogeneity was assessed using the I2 measure. Reporting bias was assessed by means of funnel plots and regression analysis. Based on 25 studies, we computed a pooled sensitivity of 72.8% (95%CI 62.4-81.3), a specificity of 99.4% (95%CI 99.0-99.7), with high heterogeneity and risk of reporting bias. More precisely, RAD tests exhibited higher sensitivity on samples with high viral load (i.e. <25 Cycle Threshold; 97.6%; 95%CI 94.1-99.0), compared to those with low viral load (≥25 Cycle Threshold; 43.6%; 95% 27.6-61.1). As the majority of collected reports were either cohort or case-control studies, deprived of preventive power analysis and often oversampling positive tests, overall performances may have been overestimated. Therefore, the massive referral to antigenic tests in place of RT-qPCR is currently questionable, and also their deployment as mass screening test may lead to intolerable share of missing diagnoses. On the other hand, RAD tests may find a significant role in primary care and in front-line settings (e.g. Emergency Departments). (www.actabiomedica.it).Keywords
This publication has 53 references indexed in Scilit:
- Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort studyThe Lancet Infectious Diseases, 2020
- Comorbidity and its impact on 1590 patients with COVID-19 in China: a nationwide analysisEuropean Respiratory Journal, 2020
- Rapid assessment of regional SARS-CoV-2 community transmission through a convenience sample of healthcare workers, the Netherlands, March 2020Eurosurveillance, 2020
- Early Transmission Dynamics in Wuhan, China, of Novel Coronavirus–Infected PneumoniaThe New England journal of medicine, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Are anti-nucleosome antibodies a better diagnostic marker than anti-dsDNA antibodies for systemic lupus erythematosus? A systematic review and a study of metanalysisAutoimmunity Reviews, 2012
- Evaluation of Sofia fluorescent immunoassay analyzer for influenza A/B virusJournal of Clinical Virology, 2012
- Accuracy of Rapid Influenza Diagnostic TestsAnnals of Internal Medicine, 2012
- Low Sensitivity of Rapid Diagnostic Test for InfluenzaClinical Infectious Diseases, 2009
- Performance of six influenza rapid tests in detecting human influenza in clinical specimensJournal of Clinical Virology, 2007