Purpose: To compare the ease of visualization and comfort of the surgeon during phacoemulsification surgery using NGENUITY ® 3D (NG) visualization system and standard operating microscope (SOM). Methods: In this prospective, randomized, single-blind, single-center study, patients undergoing phacoemulsification surgery by one of the five surgeons were randomly assigned to two groups based on the visualization modality—NG and SOM. Ease of visualization and comfort of the surgeon was assessed using a 27-parameter in-house Surgeon Comfort Score questionnaire. Results: A total of 224 phacoemulsification with intraocular lens implantations were performed in senile immature cataract (SIMC, n = 174) and mature cataract patients (MC, n = 50). Surgeon’s ease of visualization (4.92–5.00) and hand–eye coordination score (4.97–5.00) were comparable between the NG- and SOM-groups. Postoperative neck discomfort was lower in both the groups, with a relatively lower discomfort in the NG-group (score: 1.04 vs 1.56). The Spearman rank correlation coefficient ( r ) between illumination of the operation theatre room and the surgical field revealed a weak negative correlation for most of the patients in the NG-group, and a positive correlation for patients in the SOM-group. No correlation was obtained between brightness of the surgical field and comfort with the surgical field brightness. Conclusions: Similar ease of visualization was experienced by the surgeons using NG- and SOM-system. Neck discomfort postsurgery was numerically lower in the NG-group, although not significant. Additionally, the NG-system permitted the safe performance of phacoemulsification using a lower surgical field illumination.Keywords
This publication has 15 references indexed in Scilit:
- Heads-up Cataract Surgery: Complication Rates, Surgical Duration, and Comparison With Traditional MicroscopesJournal of Refractive Surgery, 2019
- Comparison of a Three-Dimensional Heads-Up Display Surgical Platform with a Standard Operating Microscope for Macular SurgeryOphthalmology Retina, 2019
- Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System2019
- Three-dimensional digital visualization of phacoemulsification and intraocular lens implantationIndian Journal Of Ophthalmology, 2019
- Phaco-Emulsification and AspirationAmerican Journal of Ophthalmology, 2018
- 3D SURGICAL VIEWING SYSTEM IN OPHTHALMOLOGYRetina, 2018
- “HEADS UP” DIGITALLY ASSISTED SURGICAL VIEWING FOR RETINAL DETACHMENT REPAIR IN A PATIENT WITH SEVERE KYPHOSISRETINAL Cases & Brief Reports, 2018
- MINIMAL ENDOILLUMINATION LEVELS AND DISPLAY LUMINOUS EMITTANCE DURING THREE-DIMENSIONAL HEADS-UP VITREORETINAL SURGERYRetina, 2017
- Phacoemulsification Outcomes with Different Illumination TechniquesEuropean Journal of Ophthalmology, 2017