We present here the design and characterization of a set of spectral calibration beads. These calibration beads are intended for the determination and regular control of the spectral characteristics of fluorescence microscopes and other fluorescence measuring devices for the readout of bead-based assays. This set consists of micrometer-sized polymer beads loaded with dyes from the liquid Calibration Kit Spectral Fluorescence Standards developed and certified by BAM for the wavelength-dependent determination of the spectral responsivity of fluorescence measuring devices like spectrofluorometers. To cover the wavelength region from 400 to 800 nm, two new near-infrared emissive dyes were included, which were spectroscopically characterized in solution and encapsulated in the beads. The resulting set of beads presents the first step towards a new platform of spectral calibration beads for the determination of the spectral characteristics of fluorescence instruments like fluorescence microscopes, FCM setups, and microtiter plate readers, thereby meeting the increasing demand for reliable and comparable fluorescence data especially in strongly regulated areas, e.g., medical diagnostics. This will eventually provide the basis for standardized calibration procedures for imaging systems as an alternative to microchannel slides containing dye solutions previously reported by us. Graphical abstractKeywords
Funding Information
- BMBF, programm KMU-innovativ: Nanotechnologie (03XP0018C / NanoGenotox”)
This publication has 37 references indexed in Scilit:
- Visible and near infrared fluorescence spectral flow cytometryCytometry Part A, 2012
- Simple strategies towards bright polymer particles via one-step staining proceduresDyes and Pigments, 2012
- State-of-the Art Comparability of Corrected Emission Spectra. 2. Field Laboratory Assessment of Calibration Performance Using Spectral Fluorescence StandardsAnalytical Chemistry, 2012
- State-of-the Art Comparability of Corrected Emission Spectra.1. Spectral Correction with Physical Transfer Standards and Spectral Fluorescence Standards by Expert LaboratoriesAnalytical Chemistry, 2012
- Utilization of microparticles in next-generation assays for microflow cytometersAnalytical and Bioanalytical Chemistry, 2010
- Photophysics of Cy3-Encapsulated Calcium Phosphate NanoparticlesNano Letters, 2009
- Calibration beads containing luminescent lanthanide ion complexesJournal of Biomedical Optics, 2009
- Near Infrared Dyes as Lifetime Solvatochromic Probes for Micropolarity Measurements of Biological SystemsBiophysical Journal, 2007
- Reliability of confocal microscopy spectral imaging systems: Use of multispectral beadsCytometry Part A, 2007
- Set of Secondary Emission Standards for Calibration of the Spectral Responsivity in Emission SpectroscopyApplied Spectroscopy, 1998